Literature DB >> 15953118

Characteristics of pupil responses during far-to-near and near-to-far accommodation.

Sanjeev Kasthurirangan1, Adrian Glasser.   

Abstract

The static and dynamic aspects of the pupil response associated with various amplitudes of far-to-near (accommodation) and near-to-far (disaccommodation) focusing responses were evaluated in this study. Dynamic refractive and pupillary changes were measured simultaneously during focusing responses to targets at real distances in 12 young (23-26 years) emmetropic subjects. The targets were presented alternately at far (6 m) and at one of six near positions from 1 D (1 m) to 6 D (16.7 cm) in 1 D steps. The latency, magnitude and peak velocity of pupil changes associated with accommodation and disaccommodation responses were calculated. The latency of refractive changes was shorter than that of pupillary changes. In general, the pupil constricted with accommodation and started dilating while accommodation was still maintained, resulting in reduced pupil dilation with disaccommodation. The magnitude of the pupil response increased linearly with that of accommodation and disaccommodation. The amount of pupil change per dioptre of refractive change was invariant with various amplitudes of refractive change. The peak velocity of pupil constriction was greater than that of pupil dilation for corresponding amplitudes. The pupil response is more closely associated with accommodation than with disaccommodation.

Mesh:

Year:  2005        PMID: 15953118     DOI: 10.1111/j.1475-1313.2005.00293.x

Source DB:  PubMed          Journal:  Ophthalmic Physiol Opt        ISSN: 0275-5408            Impact factor:   3.117


  10 in total

1.  Suitability of open-field autorefractors as pupillometers and instrument design effects.

Authors:  Carles Otero; Mikel Aldaba; Oriol Ferrer; Andrea Gascón; Juan C Ondategui-Parra; Jaume Pujol
Journal:  Int J Ophthalmol       Date:  2017-04-18       Impact factor: 1.779

2.  Simulated disparity and peripheral blur interact during binocular fusion.

Authors:  Guido Maiello; Manuela Chessa; Fabio Solari; Peter J Bex
Journal:  J Vis       Date:  2014-07-17       Impact factor: 2.240

Review 3.  Autonomic control of the eye.

Authors:  David H McDougal; Paul D Gamlin
Journal:  Compr Physiol       Date:  2015-01       Impact factor: 9.090

4.  Static and dynamic accommodation measured using the WAM-5500 Autorefractor.

Authors:  Dorothy M Win-Hall; Jamie Houser; Adrian Glasser
Journal:  Optom Vis Sci       Date:  2010-11       Impact factor: 1.973

5.  Dynamic accommodation with simulated targets blurred with high order aberrations.

Authors:  Enrique Gambra; Yinan Wang; Jing Yuan; Philip B Kruger; Susana Marcos
Journal:  Vision Res       Date:  2010-07-03       Impact factor: 1.886

6.  The influence of intrinsically-photosensitive retinal ganglion cells on the spectral sensitivity and response dynamics of the human pupillary light reflex.

Authors:  David H McDougal; Paul D Gamlin
Journal:  Vision Res       Date:  2010-01       Impact factor: 1.886

7.  Accommodative amplitude using the minus lens at different near distances.

Authors:  Hamed Momeni-Moghaddam; Jason S Ng; Bruno Mario Cesana; Abbas Ali Yekta; Mohammad Reza Sedaghat
Journal:  Indian J Ophthalmol       Date:  2017-03       Impact factor: 1.848

8.  Simultaneous Measurement of Objective and Subjective Accommodation in Response to Step Stimulation.

Authors:  Masakazu Hirota; Takeshi Morimoto; Tomomitsu Miyoshi; Takashi Fujikado
Journal:  Invest Ophthalmol Vis Sci       Date:  2020-11-02       Impact factor: 4.799

9.  Is Ocular Accommodation Influenced by Dynamic Ambient Illumination and Pupil Size?

Authors:  Hanyang Yu; Wentao Li; Ziping Chen; Mengzhen Chen; Junwen Zeng; Xijiang Lin; Feng Zhao
Journal:  Int J Environ Res Public Health       Date:  2022-08-23       Impact factor: 4.614

10.  Can Tinted Lenses Be Used to Manipulate Pupil Size and Visual Performance When Wearing Multifocal Contact Lenses?

Authors:  Hyung Min Park; Young Uk Ryu; Inn-Jee Park; Byoung Sun Chu
Journal:  Clin Optom (Auckl)       Date:  2020-03-04
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.