Literature DB >> 15950850

Tracheal width and left double-lumen tube size: a formula to estimate left-bronchial width.

Jay B Brodsky1, Harry J M Lemmens.   

Abstract

STUDY
OBJECTIVE: To determine which patient parameters best predict left bronchial width (LBW) when selecting the correct size double-lumen tube (DLT). If LBW is known, a DLT that will fit that bronchus can be chosen.
DESIGN: Prospective study.
SETTING: University medical center. PATIENTS: Three hundred twenty-one consecutive patients scheduled for thoracic surgery and for whom there was a chest radiograph and for whom tracheal width (TW) and LBW could be measured. MEASUREMENTS: Tracheal width and LBW were directly measured from the chest radiograph. Patient demographic data were recorded and then analyzed to see which factor(s) best predicted LBW. Parameters often used for DLT selection (age, sex, height, and weight) as well as TW were compared by univariate and multivariate statistical analysis to see which factor(s) most accurately predicted LBW. MAIN
RESULTS: There were weak but significant correlations between age and height and LBW in men, and height and LBW in women. Multivariate statistical analysis showed that, for both men and women, TW was the best predictor of LBW. Sex, height, and weight did not improve predictability over TW alone. The equation that best predicts LBW for both sexes is: LBWmm = (0.50)(TWmm) + 3.7 mm. This model explains 46% of the variance in LBW. As structures measured from a chest radiograph are magnified by 10%, the formula to predict LBW, which normalizes for this magnification factor, is: LBWmm = (0.45)(TWmm(CXR)) + 3.3 mm.
CONCLUSIONS: Direct airway measurement is the most accurate way to select an appropriate DLT. However, when direct measurement of LBW cannot be performed, estimating LBW from TW is a better predictor of LBW than either sex, height, or weight.

Entities:  

Mesh:

Year:  2005        PMID: 15950850     DOI: 10.1016/j.jclinane.2004.07.008

Source DB:  PubMed          Journal:  J Clin Anesth        ISSN: 0952-8180            Impact factor:   9.452


  13 in total

Review 1.  [Airway management for lung separation in thoracic surgery : An update].

Authors:  K M Meggiolaro; H Wulf; C Feldmann; T Wiesmann; A-K Schubert; J Risse
Journal:  Anaesthesist       Date:  2018-08       Impact factor: 1.041

2.  Prediction of optimal endotracheal tube cuff volume from tracheal diameter and from patient height and age: a prospective cohort trial.

Authors:  Masayuki Shibasaki; Yasufumi Nakajima; Nobuaki Shime; Teiji Sawa; Daniel I Sessler
Journal:  J Anesth       Date:  2012-03-22       Impact factor: 2.078

3.  Measurement and analysis of the tracheobronchial tree in Chinese population using computed tomography.

Authors:  Weidong Mi; Changsheng Zhang; Hong Wang; Jiangbei Cao; Changtian Li; Li Yang; Fang Guo; Xianwang Wang; Tie Yang
Journal:  PLoS One       Date:  2015-04-20       Impact factor: 3.240

4.  Selection of an appropriate left-sided double-lumen tube size for one-lung ventilation among Asians.

Authors:  Siti Salwani Ideris; Muhamad Rahimi Che Hassan; Mohd Ramzisham Abdul Rahman; Joanna Su Min Ooi
Journal:  Ann Card Anaesth       Date:  2017 Jan-Mar

5.  Dimensional Variations of Left-Sided Double-Lumen Endobronchial Tubes.

Authors:  Niels Hegland; Sebastian Schnitzler; Jan Ellensohn; Marc P Steurer; Markus Weiss; Alexander Dullenkopf
Journal:  Anesthesiol Res Pract       Date:  2019-09-24

6.  Comparison of different size left-sided double-lumen tubes for thoracic surgery.

Authors:  Raisa D Nguyen; Lakshmi N Kurnutala; Michelle A Tucci; Bryan J Hierlmeier
Journal:  Ann Card Anaesth       Date:  2021 Jan-Mar

7.  Appropriate tube size selection based on radiological images.

Authors:  Hee-Pyoung Park
Journal:  Korean J Anesthesiol       Date:  2014-03

8.  Novel patterns for the growing main bronchi in the human fetus: an anatomical, digital and statistical study.

Authors:  Michał Szpinda; Marcin Daroszewski; Alina Woźniak; Anna Szpinda; Piotr Flisiński; Małgorzata Dombek; Celestyna Mila-Kierzenkowska; Waldemar Siedlaczek
Journal:  Surg Radiol Anat       Date:  2013-06-19       Impact factor: 1.246

9.  Practice patterns of left-sided double-lumen tube: Does it match recommendation from literature - A single-centre observational pilot study.

Authors:  Prachi Kar; Archana Pathy; Ayya Syama Sundar; Ramachandran Gopinath; Srilata Moningi
Journal:  Ann Card Anaesth       Date:  2019 Jan-Mar

10.  Comparison between computerized tomography-guided bronchial width measurement versus conventional method for selection of adequate double lumen tube size.

Authors:  Praneeth Suvvari; Bhupesh Kumar; Manphool Singhal; Harkant Singh
Journal:  Ann Card Anaesth       Date:  2019 Oct-Dec
View more