Literature DB >> 15949952

Pneumatic pulsatile ventricular assist devices in children under 1 year of age.

Brigitte Stiller1, Yuguo Weng, Michael Hübler, Julia Lemmer, Nicole Nagdyman, Matthias Redlin, Peter E Lange, Roland Hetzer.   

Abstract

OBJECTIVE: Although considerable progress has been made on ventricular assist devices (VAD) for adults, pneumatic pulsatile circulatory support in young infants is still limited. There is a need for long-term ventricular assist devices to bridge the failing myocardium of young children until recovery or transplantation. Miniaturized devices and innovative modalities need to be optimized. We report on our experience.
METHODS: From 1/1992 to 6/2004, 18 infants (6 male/12 female) under 1 year of age were treated with the Berlin Heart Excor VAD. The infants were divided into two groups, depending on the year of treatment. Group A consists of eight infants resuscitated and supported with a pulsatile pneumatic ventricular assist device between 1992 and 1998 and group B consists of 10 infants treated between 1999 and 6/2004. With the pediatric-sized Berlin Heart we used miniaturized extracorporeal pneumatically driven blood pumps, the lowest stroke volume being 10 ml.
RESULTS: In 18 children, age 3-345 (median 147) days, artificial replacement of heart function was applied for long-term support (1-64, median 10 days) as a life-saving measure in our hospital. Nine had LVAD and nine BVAD support. All were in cardiogenic shock with multiorgan failure; three had fulminant myocarditis, four cardiomyopathy, and one chronic stage of congenital heart disease. Five children were weaned from the system, three reached heart transplantation, and 10 died on the VAD. There were no differences between groups A and B regarding age, body weight or diagnosis, but the duration of mechanical support differed: Group A, median 2, range 1-16 days; group B, median 12, range 1-100 days. Since 1999 (group B), the survival rate of our small infants has increased to 70% whereas none of the infants in group A survived to be discharged.
CONCLUSIONS: The outcome of VAD support in small infants is no longer inferior to that of adult support, now optimized cannulas, modified anticoagulation and optimized surgical and intensive care management have been established.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15949952     DOI: 10.1016/j.ejcts.2005.04.023

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  13 in total

1.  Ventricular assist devices: initial orientation.

Authors:  Martin Schweiger; Hitendu Dave; Frithjof Lemme; Olga Romanchenko; Michael Hofmann; Michael Hübler
Journal:  J Thorac Dis       Date:  2013-08       Impact factor: 2.895

2.  Antithrombotic therapy in neonates and children: Antithrombotic Therapy and Prevention of Thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines.

Authors:  Paul Monagle; Anthony K C Chan; Neil A Goldenberg; Rebecca N Ichord; Janna M Journeycake; Ulrike Nowak-Göttl; Sara K Vesely
Journal:  Chest       Date:  2012-02       Impact factor: 9.410

3.  Clinical experience with Berlin Heart Excor in pediatric patients in Argentina: 1373 days of cardiac support.

Authors:  Guillermo E Moreno; Alberto Charroqui; María L Pilán; Ricardo H Magliola; Mariela P Krynski; María Althabe; Luis M Landry; Gabriela Sciuccati; Alejandra Villa; Horacio Vogelfang
Journal:  Pediatr Cardiol       Date:  2011-03-20       Impact factor: 1.655

Review 4.  Pediatric ventricular assist devices.

Authors:  Francis Fynn-Thompson; Christopher Almond
Journal:  Pediatr Cardiol       Date:  2007-01-29       Impact factor: 1.655

Review 5.  An Alternative Strategy for Bridge-to-Transplant/Recovery in Small Children with Dilated Cardiomyopathy.

Authors:  Gilles Mets; Joseph Panzer; Daniël De Wolf; Thierry Bové
Journal:  Pediatr Cardiol       Date:  2017-03-29       Impact factor: 1.655

6.  Flow visualization of a pediatric ventricular assist device during stroke volume reductions related to weaning.

Authors:  Breigh N Roszelle; Steven Deutsch; William J Weiss; Keefe B Manning
Journal:  Ann Biomed Eng       Date:  2011-03-15       Impact factor: 3.934

7.  Current use of the EXCOR pediatric ventricular assist device.

Authors:  Roosevelt Bryant; Marie Steiner; James D St Louis
Journal:  J Cardiovasc Transl Res       Date:  2010-09-04       Impact factor: 4.132

8.  Factors associated with in-hospital mortality in infants undergoing heart transplantation in the United States.

Authors:  Rupali Gandhi; Christopher Almond; Tajinder P Singh; Kimberlee Gauvreau; Gary Piercey; Ravi R Thiagarajan
Journal:  J Thorac Cardiovasc Surg       Date:  2011-02       Impact factor: 5.209

9.  Bridge to transplantation with a Toyobo-NCVC left ventricular assist device in a 3-year-old girl.

Authors:  Ayumu Masuoka; Toshiyuki Katogi; Mika Iwazaki; Toshiki Kobayashi; Takashi Nishimura; Shunei Kyo
Journal:  Gen Thorac Cardiovasc Surg       Date:  2008-07-08

10.  Rational Use of Mechanical Circulatory Support as a Bridge to Pediatric and Congenital Heart Transplantation.

Authors:  Leonardo A Miana; Guilherme Viotto Rodrigues da Silva; Luiz Fernando Caneo; Aida Luisa Turquetto; Carla Tanamati; Gustavo Foronda; Maria Raquel Massoti; Juliano G Penha; Estela Azeka; Filomena R B G Galas; Fabio B Jatene; Marcelo B Jatene
Journal:  Braz J Cardiovasc Surg       Date:  2018 May-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.