Literature DB >> 15949615

Non-touch fittings in hospitals: a procedure to eradicate Pseudomonas aeruginosa contamination.

N van der Mee-Marquet1, D Bloc, L Briand, J-M Besnier, R Quentin.   

Abstract

Non-touch taps, now common in hospitals, can easily be contaminated with Pseudomonas aeruginosa. We report our experience with 87 non-touch taps in a newly built wing of our teaching hospital contaminated with P. aeruginosa from the central pipe water system. Serotyping and genotyping of strains revealed genetic diversity of isolates, but also showed that major clones were able to persist for long periods of time in non-touch taps despite chlorination. It is notoriously difficult to decontaminate such taps with biocides and disinfectants. We describe an easy and economical procedure for the eradication of P. aeruginosa contamination from non-touch taps that does not require their removal.

Entities:  

Mesh:

Year:  2005        PMID: 15949615     DOI: 10.1016/j.jhin.2004.11.023

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  8 in total

Review 1.  The role of water in healthcare-associated infections.

Authors:  Brooke K Decker; Tara N Palmore
Journal:  Curr Opin Infect Dis       Date:  2013-08       Impact factor: 4.915

2.  Should electronic faucets be used in intensive care and hematology units?

Authors:  Jacques Merrer; Emmanuelle Girou; David Ducellier; Nicole Clavreul; Florence Cizeau; Patrick Legrand; Michel Leneveu
Journal:  Intensive Care Med       Date:  2005-10-15       Impact factor: 17.440

Review 3.  Methodological approaches for monitoring opportunistic pathogens in premise plumbing: A review.

Authors:  Hong Wang; Emilie Bédard; Michèle Prévost; Anne K Camper; Vincent R Hill; Amy Pruden
Journal:  Water Res       Date:  2017-03-25       Impact factor: 11.236

4.  Analysis of black fungal biofilms occurring at domestic water taps. II: potential routes of entry.

Authors:  Guido Heinrichs; Iris Hübner; Carsten K Schmidt; G Sybren de Hoog; Gerhard Haase
Journal:  Mycopathologia       Date:  2013-02-06       Impact factor: 2.574

5.  Hospital water and opportunities for infection prevention.

Authors:  Brooke K Decker; Tara N Palmore
Journal:  Curr Infect Dis Rep       Date:  2014-10       Impact factor: 3.725

6.  Influence of pre- and post-usage flushing frequencies on bacterial water quality of non-touch water fittings.

Authors:  Miranda Suchomel; Magda Diab-Elschahawi; Michael Kundi; Ojan Assadian
Journal:  BMC Infect Dis       Date:  2013-08-30       Impact factor: 3.090

Review 7.  Pseudomonas aeruginosa in premise plumbing of large buildings.

Authors:  Emilie Bédard; Michèle Prévost; Eric Déziel
Journal:  Microbiologyopen       Date:  2016-06-28       Impact factor: 3.139

8.  Hospital Drains as Reservoirs of Pseudomonas aeruginosa: Multiple-Locus Variable-Number of Tandem Repeats Analysis Genotypes Recovered from Faucets, Sink Surfaces and Patients.

Authors:  Cindy Lalancette; Dominique Charron; Céline Laferrière; Patrick Dolcé; Eric Déziel; Michèle Prévost; Emilie Bédard
Journal:  Pathogens       Date:  2017-08-09
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.