PURPOSE: To describe a new 20-gauge transconjunctival vitrectomy procedure that we designed, to evaluate its usefulness, and to compare two different methods of use.
METHODS: The records of 431 patients (433 eyes) who underwent 20-gauge transconjunctival vitrectomy at the Surugadai Hospital of Nihon University between March 2003 and January 2004 were studied retrospectively. In surgical method 1, 20-gauge wounds were made through the conjunctiva and sclera together. In surgical method 2, 20-gauge conjunctival openings were made 2 mm posterior to the sclerotomies. Absorbable sutures were used to stitch the scleral and conjunctival openings simultaneously in both methods.
RESULTS: A 20-gauge transconjunctival vitrectomy has various benefits and is indicated for nearly all ocular diseases. Moreover, it is not limited by the intraocular instruments required. However, since cannulas were not placed in all ports, conjunctival edema occurred more easily with surgical method 2 owing to the leakage of perfusion fluid.
CONCLUSIONS: This new 20-gauge transconjunctival vitrectomy procedure has various benefits and is indicated for nearly all ocular diseases. It is not limited by the intraocular instruments required.

Entities:  

Mesh:

Year:  2005        PMID: 15944835     DOI: 10.1007/s10384-004-0183-7

Source DB:  PubMed          Journal:  Jpn J Ophthalmol        ISSN: 0021-5155            Impact factor:   2.447


  3 in total

1.  Expanded indications for 25-gauge transconjunctival vitrectomy.

Authors:  Hiroyuki Shimada; Hiroyuki Nakashizuka; Ryuzaburo Mori; Yoshihiro Mizutani
Journal:  Jpn J Ophthalmol       Date:  2005 Sep-Oct       Impact factor: 2.447

2.  Anatomical and functional outcomes of retinectomies in retinal detachments complicated by proliferative vitreoretinopathy.

Authors:  Mohammad Idrees Adhi; Nisar Siyal; Sumbul Aziz
Journal:  Saudi J Ophthalmol       Date:  2017-09-28

3.  Outcome of 20-gauge transconjunctival cannulated sutureless vitrectomy using silicone oil or air tamponade.

Authors:  Ahmed Abdel Alim Mohamed; Mohamed Abdrabbo
Journal:  Clin Ophthalmol       Date:  2013-02-19
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.