Literature DB >> 15944599

Near-infrared spectroscopy and transcutaneous oxygen pressure during exercise to detect arterial ischemia at the buttock level: comparison with arteriography.

Philippe Bouyé1, Vincent Jacquinandi, Jean Picquet, Francine Thouveny, Julien Liagre, Georges Leftheriotis, Jean-Louis Saumet, Pierre Abraham.   

Abstract

BACKGROUND: Noninvasive tests are required to detect (in both male and female subjects and side by side) arteries toward the hypogastric circulation that are likely to present significant lesions as a cause of buttock claudication.
METHODS: We compared the accuracy of near-infrared spectroscopy (NIRS) and transcutaneous oxygen pressure (TCP o 2 ) on both buttocks during walking tests to detect lesions on the arteries toward the hypogastric circulation. NIRS was considered abnormal if recovery time to pre-exercise values was greater than 240 seconds for tissue oxygen saturation (absent data being coded 0), and TCP o 2 was coded abnormal if the minimal value of buttock changes minus chest changes was lower than -15 mm Hg. The study was conducted in a university hospital; there were 30 ambulatory patients with stage 2 claudication of the Fontaine classification.
RESULTS: Angiography showed 36 abnormal (stenosis > 75%) and 24 normal arterial axes toward the buttocks circulation. NIRS and TCP o 2 provided respectively 55% (range, 41.6% to 67.9%) and 82% (range, 69.6% to 90.5%) accuracy (95% confidence interval) to predict the presence of arteriographically proven lesions; P < .05.
CONCLUSIONS: Using available cut-off points proposed in the literature, NIRS showed a lower diagnostic accuracy than TCP o 2 for the prediction of lesions on the arterial tree to the hypogastric circulation. NIRS is a recent technique as compared with TCP o 2 , and its diagnostic accuracy might improve in the future. Currently, one should carefully weigh the advantages and limits of NIRS and TCP o 2 when a choice is to be made between them to monitor exercise-induced changes resulting from lower limb arterial disease at the proximal level.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15944599     DOI: 10.1016/j.jvs.2005.03.020

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  4 in total

Review 1.  Clinical applications of near-infrared diffuse correlation spectroscopy and tomography for tissue blood flow monitoring and imaging.

Authors:  Yu Shang; Ting Li; Guoqiang Yu
Journal:  Physiol Meas       Date:  2017-02-15       Impact factor: 2.833

2.  Exercise transcutaneous oxygen pressure measurement has good sensitivity and specificity to detect lower extremity arterial stenosis assessed by computed tomography angiography.

Authors:  Caroline Koch; Emmanuel Chauve; Ségolène Chaudru; Alexis Le Faucheur; Vincent Jaquinandi; Guillaume Mahé
Journal:  Medicine (Baltimore)       Date:  2016-09       Impact factor: 1.889

3.  Endovascular aortic repair reduces gluteal oxygenation.

Authors:  Mikkel Taudorf; Michael B Nielsen; Torben V Schroeder; Lars Lönn; Henning B Nielsen
Journal:  Acta Radiol Open       Date:  2019-05-20

Review 4.  Internal Iliac Artery Stenosis: Diagnosis and How to Manage it in 2015.

Authors:  Guillaume Mahé; Adrien Kaladji; Alexis Le Faucheur; Vincent Jaquinandi
Journal:  Front Cardiovasc Med       Date:  2015-09-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.