Literature DB >> 15944530

High-resolution molecular imaging techniques for cardiovascular research.

Benjamin M W Tsui, Yuchuan Wang.   

Abstract

Mesh:

Year:  2005        PMID: 15944530     DOI: 10.1016/j.nuclcard.2005.03.005

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


× No keyword cloud information.
  8 in total

Review 1.  In vivo molecular and genomic imaging: new challenges for imaging physics.

Authors:  Simon R Cherry
Journal:  Phys Med Biol       Date:  2004-02-07       Impact factor: 3.609

2.  Optimization of geometrical calibration in pinhole SPECT.

Authors:  Dirk Bequé; Johan Nuyts; Paul Suetens; Guy Bormans
Journal:  IEEE Trans Med Imaging       Date:  2005-02       Impact factor: 10.048

3.  Design and simulation of a high-resolution stationary SPECT system for small animals.

Authors:  Freek J Beekman; Brendan Vastenhouw
Journal:  Phys Med Biol       Date:  2004-10-07       Impact factor: 3.609

4.  Pragmatic fully 3D image reconstruction for the MiCES mouse imaging PET scanner.

Authors:  Kisung Lee; Paul E Kinahan; Jeffrey A Fessler; Robert S Miyaoka; Marie Janes; Tom K Lewellen
Journal:  Phys Med Biol       Date:  2004-10-07       Impact factor: 3.609

Review 5.  PET instrumentation.

Authors:  Suleman Surti; Joel S Karp; Paul E Kinahan
Journal:  Radiol Clin North Am       Date:  2004-11       Impact factor: 2.303

6.  High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner.

Authors:  J Qi; R M Leahy; S R Cherry; A Chatziioannou; T H Farquhar
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

7.  Optimization and performance evaluation of the microPET II scanner for in vivo small-animal imaging.

Authors:  Yongfeng Yang; Yuan-Chuan Tai; Stefan Siegel; Danny F Newport; Bing Bai; Quanzheng Li; Richard M Leahy; Simon R Cherry
Journal:  Phys Med Biol       Date:  2004-06-21       Impact factor: 3.609

8.  Performance evaluation of a pinhole SPECT system for myocardial perfusion imaging of mice.

Authors:  Max C Wu; Bruce H Hasegawa; Michael W Dae
Journal:  Med Phys       Date:  2002-12       Impact factor: 4.071

  8 in total
  3 in total

1.  Small-animal molecular imaging methods.

Authors:  Robert A de Kemp; Frederick H Epstein; Ciprian Catana; Benjamin M W Tsui; Erik L Ritman
Journal:  J Nucl Med       Date:  2010-05-01       Impact factor: 10.057

2.  Integration of SimSET photon history generator in GATE for efficient Monte Carlo simulations of pinhole SPECT.

Authors:  Chia-Lin Chen; Yuchuan Wang; Jason J S Lee; Benjamin M W Tsui
Journal:  Med Phys       Date:  2008-07       Impact factor: 4.071

Review 3.  Recent advances in small-animal cardiovascular imaging.

Authors:  Benjamin M W Tsui; Dara L Kraitchman
Journal:  J Nucl Med       Date:  2009-04-16       Impact factor: 10.057

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.