Evaluation of the Cozart RapiScan drug test system for opiates and cocaine in oral fluid.

Gail Cooper1, Lisa Wilson, Claire Reid, Lianne Main, Chris Hand.   

Abstract

The purpose of this study was to evaluate the efficiency of the Cozart RapiScan (CRS) drug test system for detecting opiates and cocaine in oral fluid. Oral fluid samples were collected using the Cozart RapiScan collection system from 358 donors who were receiving treatment for their addiction and were monitored for drug misuse. A further 103 oral fluid samples were collected from volunteer donors who were not drug users. The samples were analyzed in the laboratory using the two-panel Cozart RapiScan cartridge for opiates and cocaine and confirmed using gas chromatography-mass spectrometry (GC-MS). The samples were stored frozen at -20 degrees C until analysis by GC-MS. The overall accuracy of the CRS for both opiates and cocaine was 100%. Samples spiked at 50% above and below the cut-off consistently gave negative and positive results respectively. A total of 88 samples were positive for various opiates and 111 samples were positive for cocaine and/or its metabolites. The CRS for opiates and cocaine in oral fluid, using a cut-off of 30 ng/mL morphine or benzoylecgonine equivalents in neat oral fluid, had overall efficiencies of 98% and 99%, respectively, versus GC-MS. A series of potential adulterants of oral fluid were evaluated and shown not to alter the outcome of the test result.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15944065     DOI: 10.1016/j.forsciint.2004.12.042

Source DB:  PubMed          Journal:  Forensic Sci Int        ISSN: 0379-0738            Impact factor:   2.395


  4 in total

1.  Drug testing in oral fluid.

Authors:  Olaf H Drummer
Journal:  Clin Biochem Rev       Date:  2006-08

2.  Oral fluid as an alternative matrix to monitor opiate and cocaine use in substance-abuse treatment patients.

Authors:  Riet Dams; Robin E Choo; Willy E Lambert; Hendree Jones; Marilyn A Huestis
Journal:  Drug Alcohol Depend       Date:  2006-09-27       Impact factor: 4.492

Review 3.  Oral fluid testing for drugs of abuse.

Authors:  Wendy M Bosker; Marilyn A Huestis
Journal:  Clin Chem       Date:  2009-09-10       Impact factor: 8.327

4.  Molecular gated nanoporous anodic alumina for the detection of cocaine.

Authors:  Àngela Ribes; Elisabet Xifré-Pérez; Elena Aznar; Félix Sancenón; Teresa Pardo; Lluís F Marsal; Ramόn Martínez-Máñez
Journal:  Sci Rep       Date:  2016-12-07       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.