Literature DB >> 15943515

Three-dimensional analysis of renal artery bending motion during respiration.

Mary T Draney1, Christopher K Zarins, Charles A Taylor.   

Abstract

PURPOSE: To evaluate displacement and bending of the renal arteries during respiration.
METHODS: Seven men (mean age 59+/-7 years, range 54-71) were imaged with contrast-enhanced magnetic resonance angiography (MRA). Two phases of the MRA were acquired during separate normal inspiration and expiration breath-holds. Displacement of the kidneys and renal ostia and changes in renal branch angle were measured in both coronal and axial views. Arterial curvature and distances between inspiration and expiration renal artery centerlines were computed at 1-mm intervals for the first 2 cm of each branch.
RESULTS: Significant kidney displacement was observed in both the coronal and axial views, with maximum displacement on the right side; the right kidney at expiration was 13.2+/-7 mm superior and 6.3+/-3.4 mm posterior of its position during inspiration. By comparison, the renal ostia were relatively fixed, displacing 10-fold less than the kidneys. This displacement differential resulted in significant renal branch angle changes between inspiration and expiration, with the branches being more perpendicular at expiration. Right and left branch angles were significantly different from each other in the axial view, with the right artery taking off more anteriorly. The renal artery centerlines were displaced approximately 2.5 mm at a distance of 1 cm from the ostia, with little displacement change in the second centimeter. The right renal artery was more curved than the left, with more respiratory-induced curvature change near the ostia.
CONCLUSIONS: Positional change of the kidneys during respiration induces both bending and change in angulation of the renal arteries. This bending can have a complex 3-dimensional shape near the ostia. In the setting of renal artery stenting, this motion may adversely affect the artery and/or the stent, possibly contributing to restenosis.

Entities:  

Mesh:

Year:  2005        PMID: 15943515     DOI: 10.1583/05-1530.1

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  11 in total

1.  The renal artery ostium flow diverter: structure and potential role in atherosclerosis.

Authors:  Edward B Neufeld; Zu-Xi Yu; Danielle Springer; Qing Yu; Robert S Balaban
Journal:  Atherosclerosis       Date:  2010-01-28       Impact factor: 5.162

2.  Respiration-induced deformations of the superior mesenteric and renal arteries in patients with abdominal aortic aneurysms.

Authors:  Ga-Young Suh; Gilwoo Choi; Robert J Herfkens; Ronald L Dalman; Christopher P Cheng
Journal:  J Vasc Interv Radiol       Date:  2013-07       Impact factor: 3.464

3.  Analysis of respiration-related movement of upper abdominal arteries: preliminary measurement for the development of a respiratory motion compensation technique of roadmap navigation.

Authors:  Akihiro Takemura; Masayuki Suzuki; Kiyoshi Sakamoto; Tsubasa Kitada; Hiroji Iida; Yusuke Okumura; Hajime Harauchi
Journal:  Radiol Phys Technol       Date:  2008-05-30

4.  Supraceliac and Infrarenal Aortic Flow in Patients with Abdominal Aortic Aneurysms: Mean Flows, Waveforms, and Allometric Scaling Relationships.

Authors:  Andrea S Les; Janice J Yeung; Geoffrey M Schultz; Robert J Herfkens; Ronald L Dalman; Charles A Taylor
Journal:  Cardiovasc Eng Technol       Date:  2010-03       Impact factor: 2.495

5.  Characterization of the highly nonlinear and anisotropic vascular tissues from experimental inflation data: a validation study toward the use of clinical data for in-vivo modeling and analysis.

Authors:  Kinon Chen; Bahar Fata; Daniel R Einstein
Journal:  Ann Biomed Eng       Date:  2008-07-29       Impact factor: 3.934

Review 6.  Biomechanical issues in endovascular device design.

Authors:  James E Moore
Journal:  J Endovasc Ther       Date:  2009-02       Impact factor: 3.487

7.  Respiratory-induced 3D deformations of the renal arteries quantified with geometric modeling during inspiration and expiration breath-holds of magnetic resonance angiography.

Authors:  Ga-Young Suh; Gilwoo Choi; Mary T Draney; Robert J Herfkens; Ronald L Dalman; Christopher P Cheng
Journal:  J Magn Reson Imaging       Date:  2013-04-01       Impact factor: 4.813

8.  Three-Dimensional Modeling Analysis of Visceral Arteries and Kidneys during Respiration.

Authors:  Ga-Young Suh; Gilwoo Choi; Robert J Herfkens; Ronald L Dalman; Christopher P Cheng
Journal:  Ann Vasc Surg       Date:  2016-04-24       Impact factor: 1.466

9.  Left main renal artery entrapment by diaphragmatic crura: spiral CT angiography.

Authors:  S Singham; P Murugasu; J Macintosh; P Murugasu; A Deshpande
Journal:  Biomed Imaging Interv J       Date:  2010-04-01

10.  Accuracy of registration techniques and vascular imaging modalities in fusion imaging for aortic endovascular interventions: a phantom study.

Authors:  M M Sieren; C Schareck; M Kaschwich; M Horn; F Matysiak; E Stahlberg; F Wegner; T H Oechtering; J Barkhausen; J Goltz
Journal:  CVIR Endovasc       Date:  2021-06-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.