Literature DB >> 15943502

Endovascular AAA repair with the aortomonoiliac EndoFit stent-graft: two years' experience.

Nikolaos Saratzis1, Nikolaos Melas, John Lazaridis, George Ginis, Polychronis Antonitsis, Dimitrios Lykopoulos, Athanasios Lioupis, Christos Gitas, Dimitrios Kiskinis.   

Abstract

PURPOSE: To evaluate the feasibility and efficacy of a specific aortomonoiliac endograft and the durability of the femorofemoral bypass for treatment of abdominal aortic aneurysm (AAA).
METHODS: From 2002 to 2004, 39 high-risk (ASA III/IV) patients (36 men; median age 74 years, range 63-84) with AAA (n = 33) or AAA and common iliac artery aneurysm (n = 6) were treated with an EndoFit aortomonoiliac endograft and femorofemoral crossover bypass. The contralateral iliac axis was obstructed with an endoluminal occluder. Patients were followed with contrast-enhanced computed tomography at 1, 6, 12, and 24 months.
RESULTS: EndoFit AMI stent-grafts were implanted successfully in all patients. Perioperative mortality was zero. Endoleak occurred in 3 (7.7%) cases. A proximal type I endoleak was identified at 1 month and was treated with a proximal cuff. Two type II endoleaks are under surveillance because the aneurysm sac shows no enlargement. Thrombosis of the femorofemoral graft occurred in 1 case during the immediate postoperative period due to insufficient inflow from a residual stenosis of the endograft (primary patency 97.5%). The deficit was treated successfully (secondary patency 100%). Two (5.1%) tunnel hematomas were treated conventionally. Median follow-up was 14 months (range 6-30). All patients are alive. None of the aneurysms has ruptured or been converted to an open procedure. Graft migration, serious infection, paraplegia, distal embolization, or any other serious complication has not been observed.
CONCLUSIONS: In high surgical risk patients with complex iliac anatomy, aortomonoiliac endograft with femorofemoral crossover bypass is feasible and efficacious. Moreover, the midterm patency of the extra-anatomic bypass appears quite satisfactory.

Entities:  

Mesh:

Year:  2005        PMID: 15943502     DOI: 10.1583/04-1474.1

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  1 in total

1.  Non-activated autologous platelet-rich plasma for the prevention of inguinal wound-related complications after endovascular repair of abdominal aortic aneurysms.

Authors:  Nikolaos Saratzis; Athanasios Saratzis; Nikolaos Melas; Dimitrios Kiskinis
Journal:  J Extra Corpor Technol       Date:  2008-03
  1 in total