Accuracy of newly formulated fast-setting elastomeric impression materials.

Chandur P K Wadhwani1, Glen H Johnson, Xavier Lepe, Ariel J Raigrodski.   

Abstract

STATEMENT OF PROBLEM: Elastomeric impression materials have been reformulated to achieve a faster set. The accuracy of fast-setting elastomeric impression materials should be confirmed, particularly with respect to disinfection.
PURPOSE: The purpose of this study was to assess the accuracy of 2 types of fast-setting impression materials when disinfected with acid glutaraldehyde.
MATERIAL AND METHODS: Impressions of the mandibular arch of a modified dentoform master model were made, from which gypsum working casts and dies were formed. Measurements of the master model and working casts included anteroposterior (AP) and cross-arch (CA) dimensions. A stainless steel circular crown preparation incorporated within the master model was measured in buccolingual (BL), mesiodistal (MD), and occlusogingival (OG) dimensions and compared to measurements from recovered gypsum dies. The impression materials examined were a fast-set vinyl polysiloxane (VPS-FS, Aquasil Ultra Fast Set), a fast-set polyether (PE-FS, Impregum Penta Soft Quick Step), and a regular-setting polyether as a control (PE, Impregum Penta). Disinfection involved immersion in 3.5% acid glutaraldehyde (Banicide Advanced) for 20 minutes, and nondisinfected impressions served as a control. Linear measurements were made with a measuring microscope. Statistical analysis utilized a 2-way and single-factor analysis of variance with pair-wise comparison of mean values when appropriate. Hypothesis testing was conducted at alpha = .05
RESULTS: No differences were shown between the disinfected and nondisinfected conditions for all locations. However, there were statistical differences among the 3 materials for AP, CA, MD, and OG dimensions. AP and CA dimensions of all working casts were larger than the master model. Impressions produced oval-shaped working dies for all impression materials. PE and PE-FS working dies were larger in all dimensions compared to the stainless steel preparation, whereas VPS-FS-generated working dies were reduced in OG and MD dimensions. Differences detected were small and may not be of clinical significance.
CONCLUSIONS: Impression material accuracy was unaffected by immersion disinfection. The working casts and dies were similar for PE and PE-FS. VPS-FS generated gypsum dies that were smaller in 2 of the 3 dimensions measured and may require additional die relief. Overall accuracy was acceptable for all 3 impression materials.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15942613     DOI: 10.1016/j.prosdent.2005.03.007

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  18 in total

1.  A Comparative Evaluation of the Linear Dimensional Accuracy of Four Impression Techniques using Polyether Impression Material.

Authors:  Smita Sara Manoj; K P Cherian; Vidya Chitre; Meena Aras
Journal:  J Indian Prosthodont Soc       Date:  2013-02-06

2.  Randomized controlled clinical trial on the three-dimensional accuracy of fast-set impression materials.

Authors:  Heike Rudolph; Sebastian Quaas; Manuela Haim; Jörg Preißler; Michael H Walter; Rainer Koch; Ralph G Luthardt
Journal:  Clin Oral Investig       Date:  2012-08-31       Impact factor: 3.573

3.  Digital assessment of properties of the three different generations of dental elastomeric impression materials.

Authors:  Lamia Singer; Shaymaa I Habib; Heba El-Amin Shalaby; Sayed H Saniour; Christoph Bourauel
Journal:  BMC Oral Health       Date:  2022-09-05       Impact factor: 3.747

4.  Dimensional Accuracy of Hydrophilic and Hydrophobic VPS Impression Materials Using Different Impression Techniques - An Invitro Study.

Authors:  Sreeramulu Basapogu; Ajai Pilla; Suman Pathipaka
Journal:  J Clin Diagn Res       Date:  2016-02-01

5.  Radiodensity evaluation of dental impression materials in comparison to tooth structures.

Authors:  Rodrigo Borges Fonseca; Carolina Assaf Branco; Francisco Haiter-Neto; Luciano de Souza Gonçalves; Carlos José Soares; Hugo Lemes Carlo; Mário Alexandre Coelho Sinhoreti; Lourenço Correr-Sobrinho
Journal:  J Appl Oral Sci       Date:  2010 Sep-Oct       Impact factor: 2.698

6.  The dimensional accuracy of polyvinyl siloxane impression materials using two different impression techniques: An in vitro study.

Authors:  Nirmala Kumari; D B Nandeeshwar
Journal:  J Indian Prosthodont Soc       Date:  2015 Jul-Sep

Review 7.  The elastomers for complete denture impression: A review of the literature.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2010-07-17

8.  The effect of disinfection by spray atomization on dimensional accuracy of condensation silicone impressions.

Authors:  Fariba Saleh Saber; Nader Abolfazli; Maryam Kohsoltani
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2010-12-21

9.  Comparing the Accuracy of Three Different Impression Materials in Making Duplicate Dies.

Authors:  Farshad Bajoghli; Mahmoud Sabouhi; Saeid Nosouhian; Amin Davoudi; Zeynab Behnamnia
Journal:  J Int Oral Health       Date:  2015-07

10.  The effect of disinfection with sodium hypochlorite 0.5% on dimensional stability of condensation silicone impression materials of speedex and irasil.

Authors:  Mohammad Hasan Kalantari; Afsaneh Malekzadeh; Ameneh Emami
Journal:  J Dent (Shiraz)       Date:  2014-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.