The quasi-static response of compliant prosthetic sockets for transtibial amputees using finite element methods.

Mario C Faustini1, Richard R Neptune, Richard H Crawford.   

Abstract

The finite element method (FEM) is a very powerful tool for analyzing the behavior of structures, especially when the geometry and mechanics are too complex to be modeled with analytical methods. This study focuses on the analysis of patellar tendon bearing prosthetic sockets with integrated compliant features designed to relieve contact pressure between the residual limb and socket. We developed a FEM model composed of a socket, liner and residual limb and analyzed it under quasi-static loading conditions derived from experimentally measured ground reaction forces. The geometry of the residual limb, liner and socket were acquired from computed tomography (CT) data of a transtibial amputee. Three different compliant designs were analyzed using FEM to assess the structural integrity of the sockets and their ability to relieve local pressure at the fibula head during normal walking. The compliant features consisted of thin-wall sections and two variations of spiral slots integrated within the socket wall. One version of the spiral slots produced the largest pressure relief, with an average reduction in local interface pressure during single-leg stance (20-80% of the stance phase) from 172 to 66.4 kPa or 65.8% compared to a baseline socket with no compliant features. These results suggest that the integration of local compliant features is an effective method to reduce local contact pressure and improve the functional performance of prosthetic sockets.

Mesh:

Year:  2005        PMID: 15941666     DOI: 10.1016/j.medengphy.2005.04.019

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  6 in total

1.  Efficient Computation of Cartilage Contact Pressures within Dynamic Simulations of Movement.

Authors:  Colin R Smith; Kwang Won Choi; Dan Negrut; Darryl G Thelen
Journal:  Comput Methods Biomech Biomed Eng Imaging Vis       Date:  2016-05-13

2.  A digital patient for computer-aided prosthesis design.

Authors:  Giorgio Colombo; Giancarlo Facoetti; Caterina Rizzi
Journal:  Interface Focus       Date:  2013-04-06       Impact factor: 3.906

3.  A finite element model to assess transtibial prosthetic sockets with elastomeric liners.

Authors:  John C Cagle; Per G Reinhall; Kate J Allyn; Jake McLean; Paul Hinrichs; Brian J Hafner; Joan E Sanders
Journal:  Med Biol Eng Comput       Date:  2017-12-13       Impact factor: 2.602

Review 4.  Technologies to monitor the health of loaded skin tissues.

Authors:  Dan L Bader; Peter R Worsley
Journal:  Biomed Eng Online       Date:  2018-04-12       Impact factor: 2.819

5.  ARACAM: A RGB-D Multi-View Photogrammetry System for Lower Limb 3D Reconstruction Applications.

Authors:  Marco A Barreto; Jorge Perez-Gonzalez; Hugh M Herr; Joel C Huegel
Journal:  Sensors (Basel)       Date:  2022-03-22       Impact factor: 3.576

6.  Template models for simulation of surface manipulation of musculoskeletal extremities.

Authors:  Sean Doherty; Ben Landis; Tammy M Owings; Ahmet Erdemir
Journal:  PLoS One       Date:  2022-08-15       Impact factor: 3.752

  6 in total