Two-beam optical traps: refractive index and size measurements of microscale objects.

Richard A Flynn1, Bing Shao, Mirianas Chachisvilis, Mihrimah Ozkan, Sadik C Esener.   

Abstract

A counter-propagating optical trap measurement (COTM) system is proposed and analyzed based on the ray-optics model. In this system, refractive index and size of trapped objects can be estimated by using forward scattered light from the two-beam laser trap with resolution Delta n = 0.013 for the refractive index measurements and 3.3% for the size measurements, which is comparable with current bulk techniques, such as refractometry, and flow cytometry. The unique advantage of the COTM system over conventional approaches lies in its capability of marker-free single-particle characterization in whatever transparent buffer required by living cell, eliminating the necessity of changing the fluid composition of the sample in refractometry, and of tagging target with toxic fluorescence dyes in flow cytometry. Noise analysis predicts a potential improvement in the system resolution by more than two orders of magnitude. This non-invasive and sterile tool complements lab-on-a-chips with single cell manipulation and analysis in living friendly ambient.

Mesh:

Substances:

Year:  2005        PMID: 15940421     DOI: 10.1007/s10544-005-1586-z

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  2 in total

Review 1.  Lab-on-a-Chip Technologies for the Single Cell Level: Separation, Analysis, and Diagnostics.

Authors:  Axel Hochstetter
Journal:  Micromachines (Basel)       Date:  2020-04-29       Impact factor: 2.891

2.  Quantitative refractive index distribution of single cell by combining phase-shifting interferometry and AFM imaging.

Authors:  Qinnan Zhang; Liyun Zhong; Ping Tang; Yingjie Yuan; Shengde Liu; Jindong Tian; Xiaoxu Lu
Journal:  Sci Rep       Date:  2017-05-31       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.