Literature DB >> 15937972

Likelihood ratio for trisomy 21 in fetuses with tricuspid regurgitation at the 11 to 13 + 6-week scan.

S Faiola1, E Tsoi, I C Huggon, L D Allan, K H Nicolaides.   

Abstract

OBJECTIVE: To determine the likelihood ratio for trisomy 21 in fetuses with tricuspid regurgitation at the 11 to 13 + 6-week scan.
METHODS: Fetal echocardiography was carried out by specialist pediatric cardiologists in 742 singleton pregnancies at 11 to 13 + 6 weeks' gestation and pulsed wave Doppler was used to ascertain the presence or absence of tricuspid regurgitation. To avoid confusion with other adjacent signals, a strict definition of tricuspid regurgitation was used, in that it had to occupy at least half of systole and reach a velocity of over 80 cm/s. The fetal crown-rump length (CRL) and the nuchal translucency (NT) thickness were measured and the presence of any congenital heart abnormality noted. Follow-up of the pregnancy was carried out to determine the presence of chromosomal abnormalities. The likelihood ratio for trisomy 21 in fetuses with and without tricuspid regurgitation was determined.
RESULTS: The tricuspid valve was successfully examined in 718 (96.8%) cases. Tricuspid regurgitation was present in 39 (8.5%) of the 458 chromosomally normal fetuses, in 82 (65.1%) of the 126 with trisomy 21, in 44 (53.0%) of the 83 with trisomy 18 or 13, and in 11 (21.6%) of the 51 with other chromosomal defects. The prevalence of tricuspid regurgitation was also associated with fetal CRL, delta NT and the presence of cardiac defects. Logistic regression analysis, irrespective of cardiac defects, demonstrated that in the chromosomally normal fetuses significant independent prediction of the likelihood of tricuspid regurgitation was provided by fetal delta NT (odds ratio (OR), 1.26; 95% CI, 1.34-1.41; P < 0.0001), while in trisomy 21 fetuses prediction was provided by CRL (OR, 0.94; 95% CI, 0.89-0.99; P = 0.021). The likelihood ratio for trisomy 21 for tricuspid regurgitation was derived by dividing the likelihood in trisomy 21 by that in normal fetuses. In the chromosomally normal fetuses, the prevalence of tricuspid regurgitation in those with cardiac defects was 46.9% and 5.6% in those without cardiac defects, and the likelihood ratio of tricuspid regurgitation for cardiac defects was 8.4.
CONCLUSION: At 11 to 13 + 6 weeks' gestation, there is a high association between tricuspid regurgitation and trisomy 21, as well as other chromosomal defects. The prevalence of tricuspid regurgitation increases with fetal NT thickness and is substantially higher in those with, than those without, a cardiac defect. Copyright (c) 2005 ISUOG.

Entities:  

Mesh:

Year:  2005        PMID: 15937972     DOI: 10.1002/uog.1922

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  6 in total

1.  Retrospective study evaluating the performance of a first-trimester combined screening for trisomy 21 in an Italian unselected population.

Authors:  Francesco Padula; Pietro Cignini; Diana Giannarelli; Cristiana Brizzi; Claudio Coco; Laura D'Emidio; Elsa Giorgio; Maurizio Giorlandino; Lucia Mangiafico; Marialuisa Mastrandrea; Vincenzo Milite; Luisa Mobili; Cinzia Nanni; Raffaella Raffio; Cinzia Taramanni; Roberto Vigna; Alvaro Mesoraca; Domenico Bizzoco; Ivan Gabrielli; Gianluca Di Giacomo; Maria Antonietta Barone; Antonella Cima; Francesca Romana Giorlandino; Sabrina Emili; Marina Cupellaro; Claudio Giorlandino
Journal:  J Prenat Med       Date:  2014 Apr-Jun

Review 2.  Sonographic markers for early diagnosis of fetal malformations.

Authors:  Maria Daniela Renna; Paola Pisani; Francesco Conversano; Emanuele Perrone; Ernesto Casciaro; Gian Carlo Di Renzo; Marco Di Paola; Antonio Perrone; Sergio Casciaro
Journal:  World J Radiol       Date:  2013-10-28

3.  Increased nuchal traslucency in normal karyotype fetuses.

Authors:  Roberta De Domenico; Marianna Faraci; Entela Hyseni; Fosca A F Di Prima; Oriana Valenti; Santo Monte; Elsa Giorgio; Eliana Renda
Journal:  J Prenat Med       Date:  2011-04

4.  Doppler assessment of the ductus venosus and the tricuspid valve at 11-13+6 weeks: Reference ranges and development of sonographic quality assurance standards.

Authors:  Vanessa Pincham; Jon Hyett; Karen Pollard; Philip Schluter; Andrew McLennan
Journal:  Australas J Ultrasound Med       Date:  2016-02-21

5.  Safety Indices during Fetal Echocardiography at the Time of First-Trimester Scan Are Machine Dependent.

Authors:  Dragos Nemescu; Anca Berescu; Mircea Onofriescu; Dan Bogdan Navolan; Cristian Rotariu
Journal:  PLoS One       Date:  2015-05-27       Impact factor: 3.240

Review 6.  First Trimester Ultrasound in Prenatal Diagnosis-Part of the Turning Pyramid of Prenatal Care.

Authors:  Ran Neiger
Journal:  J Clin Med       Date:  2014-09-05       Impact factor: 4.241

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.