Literature DB >> 15937718

System integration and DICOM image creation for PET-MR fusion.

Chia-Hung Hsiao1, Tsair Kao, Yu-Hua Fang, Jiunn-Kuen Wang, Wan-Yuo Guo, Liang-Hsiao Chao, Sang-Hue Yen.   

Abstract

This article demonstrates a gateway system for converting image fusion results to digital imaging and communication in medicine (DICOM) objects. For the purpose of standardization and integration, we have followed the guidelines of the Integrated Healthcare Enterprise technical framework and developed a DICOM gateway. The gateway system combines data from hospital information system, image fusion results, and the information generated itself to constitute new DICOM objects. All the mandatory tags defined in standard DICOM object were generated in the gateway system. The gateway system will generate two series of SOP instances of each PET-MR fusion result; SOP (Service Object Pair) one for the reconstructed magnetic resonance (MR) images and the other for position emission tomography (PET) images. The size, resolution, spatial coordinates, and number of frames are the same in both series of SOP instances. Every new generated MR image exactly fits with one of the reconstructed PET images. Those DICOM images are stored to the picture archiving and communication system (PACS) server by means of standard DICOM protocols. When those images are retrieved and viewed by standard DICOM viewing systems, both images can be viewed at the same anatomy location. This system is useful for precise diagnosis and therapy.

Entities:  

Mesh:

Year:  2005        PMID: 15937718      PMCID: PMC3047215          DOI: 10.1007/s10278-004-1024-4

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  11 in total

1.  Designing and implementing the transition to a fully digital hospital.

Authors:  S A Pavlopoulos; A N Delopoulos
Journal:  IEEE Trans Inf Technol Biomed       Date:  1999-03

2.  Registration of magnetic resonance spectroscopic imaging to computed tomography for radiotherapy treatment planning.

Authors:  E E Graves; A Pirzkall; S J Nelson; D Larson; L Verhey
Journal:  Med Phys       Date:  2001-12       Impact factor: 4.071

3.  An imaging co-registration system using novel non-invasive and non-radioactive external markers.

Authors:  Tung-Hsin Wu; Jiunn-Kuen Wang; Jason J S Lee; Ren-Shyan Liu; Wan-Yuo Guo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-04-12       Impact factor: 9.236

Review 4.  CT-SPECT fusion for analysis of radiolabeled antibodies: applications in gastrointestinal and lung carcinoma.

Authors:  E L Kramer; M E Noz
Journal:  Int J Rad Appl Instrum B       Date:  1991

5.  Minimizing Digital Imaging and Communications in Medicine (DICOM) Modality Worklist patient/study selection errors.

Authors:  P M Kuzmak; R E Dayhoff
Journal:  J Digit Imaging       Date:  2001-06       Impact factor: 4.056

Review 6.  DICOM versus HL7 for modality interfacing.

Authors:  H Oosterwijk
Journal:  J Digit Imaging       Date:  1998-08       Impact factor: 4.056

7.  MERIT-9: a patient information exchange guideline using MML, HL7 and DICOM.

Authors:  M Kimura; K Ohe; H Yoshihara; Y Ando; F Kawamata; F Tsuchiya; H Furukawa; S Horiguchi; T Sakusabe; S Tani; M Akiyama
Journal:  Int J Med Inform       Date:  1998-07       Impact factor: 4.046

8.  The brain: integrated three-dimensional display of MR and PET images.

Authors:  D N Levin; X P Hu; K K Tan; S Galhotra; C A Pelizzari; G T Chen; R N Beck; C T Chen; M D Cooper; J F Mullan
Journal:  Radiology       Date:  1989-09       Impact factor: 11.105

9.  Head and neck nodal station images: guidance for three-dimensional radiation therapy treatment planning.

Authors:  Sang H Yen; Liang S Chao; Shueh C Liou; Chia H Hsiao; Yuh L Lee; Max M Chao
Journal:  J Digit Imaging       Date:  2003-01-21       Impact factor: 4.056

10.  Three-dimensional registration of cardiac positron emission tomography attenuation scans.

Authors:  S L Bacharach; M A Douglas; R E Carson; P J Kalkowski; N M Freedman; P Perrone-Filardi; R O Bonow
Journal:  J Nucl Med       Date:  1993-02       Impact factor: 10.057

View more
  1 in total

1.  PET/CT fusion viewing software for use with picture archiving and communication systems.

Authors:  Ki Chun Im; Ik Soo Choi; Jin-Sook Ryu; Gi Seoung Eo; Jae Seung Kim; Dae Hyuk Moon
Journal:  J Digit Imaging       Date:  2009-08-06       Impact factor: 4.056

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.