Literature DB >> 15935960

The effects of interelectrode distance on electromyographic amplitude and mean power frequency during isokinetic and isometric muscle actions of the biceps brachii.

Travis W Beck1, Terry J Housh, Glen O Johnson, Joseph P Weir, Joel T Cramer, Jared W Coburn, Moh H Malek.   

Abstract

The purpose of this study was to examine the effects of interelectrode distance (IED) on the absolute and normalized electromyographic (EMG) amplitude and mean power frequency (MPF) versus isokinetic and isometric torque relationships for the biceps brachii muscle. Ten adults [mean+/-SD age=22.0+/-3.4 years] performed submaximal to maximal, isokinetic and isometric muscle actions of the dominant forearm flexors. Following determination of isokinetic peak torque (PT) and the isometric maximum voluntary contraction (MVC), the subjects performed randomly ordered, submaximal step muscle actions in 10% increments from 10% to 90% PT and MVC. Surface EMG signals were recorded simultaneously from bipolar electrode arrangements placed over the biceps brachii muscle with IEDs of 20, 40, and 60mm. Absolute and normalized EMG amplitude (muVrms and %max) increased linearly with torque during the isokinetic and isometric muscle actions (r(2) range=0.988-0.998), but there were no significant changes for absolute or normalized EMG MPF (Hz or %max) from 10% to 100% PT and MVC. In some cases, there were significant (p<0.05) differences among the three IED arrangements for absolute EMG amplitude and MPF values, but not for the normalized values. These findings suggested that for the biceps brachii muscle, IEDs between 20 and 60mm resulted in similar patterns for the EMG amplitude or MPF versus dynamic and isometric torque relationships. Furthermore, unlike the absolute EMG amplitude and MPF values, the normalized EMG data were not influenced by changes in IED between 20 and 60mm. Thus, normalized EMG data can be compared among previous studies that have utilized different IED arrangements.

Mesh:

Year:  2005        PMID: 15935960     DOI: 10.1016/j.jelekin.2004.12.001

Source DB:  PubMed          Journal:  J Electromyogr Kinesiol        ISSN: 1050-6411            Impact factor:   2.368


  7 in total

1.  A spectral analysis of rotator cuff musculature electromyographic activity: surface and indwelling.

Authors:  Sherry I Backus; Daniel P Tomlinson; Bavornrat Vanadurongwan; Mark W Lenhoff; Frank A Cordasco; Eric L Chehab; Ronald S Adler; R Frank Henn; Howard J Hillstrom
Journal:  HSS J       Date:  2010-08-13

2.  Evaluation of EMG processing techniques using Information Theory.

Authors:  Fernando D Farfán; Julio C Politti; Carmelo J Felice
Journal:  Biomed Eng Online       Date:  2010-11-12       Impact factor: 2.819

3.  Monitoring Involuntary Muscle Activity in Acute Patients with Upper Motor Neuron Lesion by Wearable Sensors: A Feasibility Study.

Authors:  Andrea Merlo; Maria Giulia Montecchi; Francesco Lombardi; Xhejsi Vata; Aurora Musi; Mirco Lusuardi; Roberto Merletti; Isabella Campanini
Journal:  Sensors (Basel)       Date:  2021-04-30       Impact factor: 3.576

4.  Pilates training improves 5-km run performance by changing metabolic cost and muscle activity in trained runners.

Authors:  Paula Finatto; Edson Soares Da Silva; Alexandre B Okamura; Bruna P Almada; Jorge L L Storniolo; Henrique B Oliveira; Leonardo A Peyré-Tartaruga
Journal:  PLoS One       Date:  2018-03-21       Impact factor: 3.240

5.  Effect of exercise-induced muscle damage on vascular function and skeletal muscle microvascular deoxygenation.

Authors:  Jacob T Caldwell; Garrett C Wardlow; Patrece A Branch; Macarena Ramos; Christopher D Black; Carl J Ade
Journal:  Physiol Rep       Date:  2016-11

6.  Kinesiological Analysis of Stationary Running Performed in Aquatic and Dry Land Environments.

Authors:  Cristine Lima Alberton; Stephanie Santana Pinto; Natália Amélia da Silva Azenha; Eduardo Lusa Cadore; Marcus Peikriszwili Tartaruga; Bruno Brasil; Luiz Fernando Martins Kruel
Journal:  J Hum Kinet       Date:  2015-12-30       Impact factor: 2.193

7.  A computational model to investigate the effect of pennation angle on surface electromyogram of Tibialis Anterior.

Authors:  Diptasree Maitra Ghosh; Dinesh Kumar; Sridhar Poosapadi Arjunan; Ariba Siddiqi; Ramakrishnan Swaminathan
Journal:  PLoS One       Date:  2017-12-07       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.