Literature DB >> 15935272

Clinical performance of metal-free polymer crowns after 3 years in service.

Peter Rammelsberg1, Katrin Spiegl, Grit Eickemeyer, Marc Schmitter.   

Abstract

OBJECTIVE: To investigate the influence of location and preparation design on the survival and complication rate of metal-free polymer crowns within a prospective clinical study.
METHODS: After randomization, a total of 114 (68 posterior and 46 anterior) single crowns were prepared, either with a chamfer finishing line or with a shoulder combined with occlusal reduction of at least 1 mm. Build-ups were made with a composite material, using the corresponding dentin adhesive. After making impressions with polyether material, polymer crowns were manufactured on stone dies and adhesively luted with resin cement. Follow-ups were scheduled after 1 month, 1 year, 2 years and 3 years. Documentation included failures and other complications, as well as ratings of esthetic and functional performance. After 3 years, data from 100 single crowns were statistically evaluated.
RESULTS: Within a minimal observation period of 3 years, 10 complications occurred, including 3 total fractures, 3 partial fractures and 3 decementations. Only 4 crowns (3 total fractures +1 partial fracture) had to be replaced, whereas 2 partial fractures could be repaired and all loosened crowns could be recemented. Kaplan-Meier survival analysis did not show any influence of location or preparation design on the complication rate. Esthetic and functional evaluation by the patients revealed a high acceptance of single polymer crowns, indicated by medians of 9-10 on a 10-point-scale.
CONCLUSION: Within the 3 year observation period, it can be concluded that 0.5 mm chamfer and shoulder preparation ensure that the stability of metal-free polymer crowns for anterior and posterior teeth is acceptable. Long-term stability and wear behavior has still to be evaluated.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15935272     DOI: 10.1016/j.jdent.2004.11.012

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  5 in total

1.  CEREC CAD/CAM Chairside System.

Authors:  G Sannino; F Germano; L Arcuri; E Bigelli; C Arcuri; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2015-04-13

2.  First clinical experiences with CAD/CAM-fabricated PMMA-based fixed dental prostheses as long-term temporaries.

Authors:  Fabian Huettig; Andreas Prutscher; Christoph Goldammer; Curt A Kreutzer; Heiner Weber
Journal:  Clin Oral Investig       Date:  2015-04-22       Impact factor: 3.573

3.  Fracture Resistance of Anterior Crowns Reinforced by Short-Fiber Composite.

Authors:  Lippo Lassila; Anssi Haapsaari; Pekka K Vallittu; Sufyan Garoushi
Journal:  Polymers (Basel)       Date:  2022-04-28       Impact factor: 4.967

4.  Three-dimensional finite element analysis of the stress distribution pattern in a mandibular first molar tooth restored with five different restorative materials.

Authors:  Kathleen Manuela D'souza; Meena Ajay Aras
Journal:  J Indian Prosthodont Soc       Date:  2017 Jan-Mar

5.  In vitro evaluation of the marginal and internal discrepancies of different esthetic restorations.

Authors:  Amal Abdelsamad Sakrana
Journal:  J Appl Oral Sci       Date:  2013 Nov-Dec       Impact factor: 2.698

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.