Literature DB >> 15934197

The FLUKA code: new developments and application to 1 GeV/n iron beams.

H Aiginger1, V Andersen, F Ballarini, G Battistoni, M Campanella, M Carboni, F Cerutti, A Empl, W Enghardt, A Fassò, A Ferrari, E Gadioli, M V Garzelli, K Lee, A Ottolenghi, K Parodi, M Pelliccioni, L Pinsky, J Ranft, S Roesler, P R Sala, D Scannicchio, G Smirnov, F Sommerer, T Wilson, N Zapp.   

Abstract

The modeling of ion transport and interactions in matter is a subject of growing interest, driven by the continuous increase of possible application fields. These include hadron therapy, dosimetry, and space missions, but there are also several issues involving fundamental research, accelerator physics, and cosmic ray physics, where a reliable description of heavy ion induced cascades is important. In the present work, the capabilities of the FLUKA code for ion beams will be briefly recalled and some recent developments presented. Applications of the code to the simulation of therapeutic carbon, nitrogen and oxygen ion beams, and of iron beams, which are of direct interest for space mission related experiments, will be also presented together with interesting consideration relative to the evaluation of dosimetric quantities. Both applications involve ion beams in the AGeV range. c2005 Published by Elsevier Ltd on behalf of COSPAR.

Entities:  

Keywords:  NASA Discipline Radiation Health; Non-NASA Center

Mesh:

Substances:

Year:  2005        PMID: 15934197     DOI: 10.1016/j.asr.2005.01.090

Source DB:  PubMed          Journal:  Adv Space Res        ISSN: 0273-1177            Impact factor:   2.152


  3 in total

1.  Nontargeted stressful effects in normal human fibroblast cultures exposed to low fluences of high charge, high energy (HZE) particles: kinetics of biologic responses and significance of secondary radiations.

Authors:  Géraldine Gonon; Jean-Emmanuel Groetz; Sonia M de Toledo; Roger W Howell; Michel Fromm; Edouard I Azzam
Journal:  Radiat Res       Date:  2013-03-06       Impact factor: 2.841

Review 2.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

3.  The FLUKA Code: An Accurate Simulation Tool for Particle Therapy.

Authors:  Giuseppe Battistoni; Julia Bauer; Till T Boehlen; Francesco Cerutti; Mary P W Chin; Ricardo Dos Santos Augusto; Alfredo Ferrari; Pablo G Ortega; Wioletta Kozłowska; Giuseppe Magro; Andrea Mairani; Katia Parodi; Paola R Sala; Philippe Schoofs; Thomas Tessonnier; Vasilis Vlachoudis
Journal:  Front Oncol       Date:  2016-05-11       Impact factor: 6.244

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.