Average glandular dose in routine mammography screening using a Sectra MicroDose Mammography unit.

Bengt Hemdal1, Lars Herrnsdorf, Ingvar Andersson, Gert Bengtsson, Boel Heddson, Magnus Olsson.   

Abstract

The Sectra MicroDose Mammography system is based on direct photon counting (with a solid-state detector), and a substantially lower dose to the breast than when using conventional systems can be expected. In this work absorbed dose measurements have been performed for the first unit used in routine mammography screening (at the Hospital of Helsingborg, Sweden). Two European protocols on dosimetry in mammography have been followed. Measurement of half value layer (HVL) cannot be performed as prescribed, but this study has demonstrated that non-invasive measurements of HVL can be performed accurately with a sensitive and well collimated solid-state detector with simultaneous correction for the energy dependence. The average glandular dose for a 50 mm standard breast with 50% glandularity, simulated by 45 mm polymethylmethacrylate, was found to be 0.21 and 0.28 mGy in March and December 2004, respectively. These values are much lower than for any other mammography system on the market today. It has to be stressed that the measurements were made using the current clinical settings and that no systematic optimisation of the relationship between absorbed dose and diagnostic image quality has been performed within the present study. In order to further increase the accuracy of absorbed dose measurements for this unit, the existing dose protocols should be revised to account also for the tungsten/aluminium anode/filter combination, the multi-slit pre-collimator device and the occurrence of a dose profile in the scanning direction.

Entities:  

Mesh:

Year:  2005        PMID: 15933152     DOI: 10.1093/rpd/nch556

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  4 in total

1.  Detection of simulated microcalcifications in a phantom with digital mammography: effect of pixel size.

Authors:  Sankararaman Suryanarayanan; Andrew Karellas; Srinivasan Vedantham; Ioannis Sechopoulos; Carl J D'Orsi
Journal:  Radiology       Date:  2007-05-23       Impact factor: 11.105

2.  A review: Development of a microdose model for analysis of adaptive response and bystander dose response behavior.

Authors:  Bobby E Leonard
Journal:  Dose Response       Date:  2008-02-27       Impact factor: 2.658

3.  Musculoskeletal imaging with a prototype photon-counting detector.

Authors:  M Gruber; P Homolka; M Chmeissani; M Uffmann; M Pretterklieber; F Kainberger
Journal:  Eur Radiol       Date:  2011-08-27       Impact factor: 5.315

4.  Quality assurance and quality control in mammography: a review of available guidance worldwide.

Authors:  Cláudia Reis; Ana Pascoal; Taxiarchis Sakellaris; Manthos Koutalonis
Journal:  Insights Imaging       Date:  2013-08-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.