Literature DB >> 15933096

Skin dose measurements on patients for diagnostic and interventional neuroradiology: a multicentre study.

L Struelens1, F Vanhavere, H Bosmans, R Van Loon, H Mol.   

Abstract

The present study reports on the skin dose measurements on patients undergoing diagnostic and interventional neuroradiology procedures. Grids of thermoluminescence dosemeters were attached on the head of the patient. The exposure parameters of the X-ray systems and the clinical procedures were fully documented. While for the diagnostic procedure, the dose threshold of 2 Gy for deterministic effects was not reached, this situation was much different for the embolisations. For angiography of the carotid arteries, no skin doses were measured >320 mGy. For the cerebral embolisations, maximum skin doses up to 5.4 Gy were measured. Doses to the patients varied largely between different hospitals and within the same hospital for similar procedures. On the one hand, the complexity of the pathology for interventional procedures was responsible for the large variability in dose. On the other hand, large differences in clinical protocol and technical parameters of the X-ray systems, explaining the dose variations, were also observed. A correlation was found between the maximum skin dose measured on a patient and the total dose-area product (DAP) value for cerebral embolisations. This correlation makes it possible to estimate the maximum skin dose from these DAP values and to determine a trigger level. In conclusion, management of patient doses in interventional radiology requires training, specialisation and well-documented procedure guidelines.

Entities:  

Mesh:

Year:  2005        PMID: 15933096     DOI: 10.1093/rpd/nch537

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  7 in total

1.  Cumulative radiation dose during hospitalization for aneurysmal subarachnoid hemorrhage.

Authors:  S I Moskowitz; W J Davros; M E Kelly; D Fiorella; P A Rasmussen; T J Masaryk
Journal:  AJNR Am J Neuroradiol       Date:  2010-05-27       Impact factor: 3.825

2.  Brain radiation doses to patients in an interventional neuroradiology laboratory.

Authors:  R M Sanchez; E Vano; J M Fernández; M Moreu; L Lopez-Ibor
Journal:  AJNR Am J Neuroradiol       Date:  2014-03-13       Impact factor: 3.825

3.  Patient radiation dose in diagnostic and interventional procedures for intracranial aneurysms: experience at a single center.

Authors:  Chang Woo Chun; Bum-Soo Kim; Cheol Hyoun Lee; Yon Kwon Ihn; Yong-Sam Shin
Journal:  Korean J Radiol       Date:  2014-11-07       Impact factor: 3.500

4.  Patient skin dose during neuroembolization by multiple-point measurement using a radiosensitive indicator.

Authors:  S Suzuki; S Furui; Y Matsumaru; S Nobuyuki; M Ebara; T Abe; D Itoh
Journal:  AJNR Am J Neuroradiol       Date:  2008-04-03       Impact factor: 3.825

5.  Patient Radiation Exposure During Diagnostic and Therapeutic Procedures for Intracranial Aneurysms: A Multicenter Study.

Authors:  Yon Kwon Ihn; Bum-Soo Kim; Jun Soo Byun; Sang Hyun Suh; Yoo Dong Won; Deok Hee Lee; Byung Moon Kim; Young Soo Kim; Pyong Jeon; Chang-Woo Ryu; Sang-Il Suh; Dae Seob Choi; See Sung Choi; Jin Wook Choi; Hyuk Won Chang; Jae-Wook Lee; Sang Heum Kim; Young Jun Lee; Shang Hun Shin; Soo Mee Lim; Woong Yoon; Hae Woong Jeong; Moon Hee Han
Journal:  Neurointervention       Date:  2016-09-03

Review 6.  Practice of ALARA in the pediatric interventional suite.

Authors:  Bairbre Connolly; John Racadio; Richard Towbin
Journal:  Pediatr Radiol       Date:  2006-09

7.  Pediatric minor head trauma: do cranial CT scans change the therapeutic approach?

Authors:  Felipe P Andrade; Roberto Montoro; Renan Oliveira; Gabriela Loures; Luana Flessak; Roberta Gross; Camille Donnabella; Andrea Puchnick; Lisa Suzuki; Rodrigo Regacini
Journal:  Clinics (Sao Paulo)       Date:  2016-10-01       Impact factor: 2.365

  7 in total