Literature DB >> 15932828

First-trimester ductus venosus, nasal bones, and Down syndrome in a high-risk population.

Federico Prefumo1, Farah Sethna, Shanthi Sairam, Amarnath Bhide, Baskaran Thilaganathan.   

Abstract

OBJECTIVE: Assessing the role of fetal ductus venosus and nasal bones evaluation in first-trimester screening for Down syndrome.
METHODS: This was a prospective cohort study in a tertiary referral fetal medicine unit involving 628 consecutive fetuses undergoing chorionic villus sampling. The indication for chorionic villus sampling was an increased risk (more than 1:300) for trisomy 21 based on maternal age and nuchal translucency screening in 313 cases (54.7%), increased maternal age in 195 (34.1%), and other in 64 (11.2%). Immediately before chorionic villus sampling, an ultrasound examination was performed. The pattern of blood flow in the ductus venosus and the presence or absence of the nasal bones was noted.
RESULTS: A satisfactory examination of both ductus venosus and nasal bones was possible in 572 fetuses. Of these, 497 (86.9%) had a normal karyotype, and 47 (8.2%) were affected with Down syndrome. The likelihood ratio for trisomy 21 was 7.05 (95% confidence interval 4.27-11.64) in the case of abnormal ductus venosus flow and 6.42 (95% confidence interval 3.86-10.67) in the case of absent nasal bones.
CONCLUSION: In addition to increased fetal nuchal translucency, Down syndrome is significantly associated with first-trimester abnormal flow velocity patterns in the ductus venosus and hypoplasia of the nasal bones.

Entities:  

Mesh:

Year:  2005        PMID: 15932828     DOI: 10.1097/01.AOG.0000161368.77506.ab

Source DB:  PubMed          Journal:  Obstet Gynecol        ISSN: 0029-7844            Impact factor:   7.661


  3 in total

Review 1.  First trimester ultrasound tests alone or in combination with first trimester serum tests for Down's syndrome screening.

Authors:  S Kate Alldred; Yemisi Takwoingi; Boliang Guo; Mary Pennant; Jonathan J Deeks; James P Neilson; Zarko Alfirevic
Journal:  Cochrane Database Syst Rev       Date:  2017-03-15

2.  Employ ductus venous blood flow in the early detection of trisomy 21, trisomy 18, and trisomy 13: A meta-analysis.

Authors:  Yibing Ge; Lili Xia; Yun Wu; Hongbao Cao
Journal:  Medicine (Baltimore)       Date:  2019-03       Impact factor: 1.889

Review 3.  Harmony Behind the Trumped-Shaped Vessel: the Essential Role of the Ductus Venosus in Fetal Medicine.

Authors:  Sifa Turan; Ozhan M Turan
Journal:  Balkan Med J       Date:  2018-03-15       Impact factor: 2.021

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.