Literature DB >> 15925457

Comparing step-and-shoot IMRT with dynamic helical tomotherapy IMRT plans for head-and-neck cancer.

Marco van Vulpen1, Colin Field, Cornelis P J Raaijmakers, Matthew B Parliament, Chris H J Terhaard, Marc A MacKenzie, Rufus Scrimger, Jan J W Lagendijk, B Gino Fallone.   

Abstract

PURPOSE: The goal of this planning study was to compare step-and-shoot intensity-modulated radiotherapy (IMRT) plans with helical dynamic IMRT plans for oropharynx patients on the basis of dose distribution. METHODS AND MATERIALS: Five patients with oropharynx cancer had been previously treated by step-and-shoot IMRT at the University Medical Centre Utrecht, The Netherlands, applying five fields and approximately 60-90 segments. Inverse planning was carried out using Plato, version 2.6.2. For each patient, an inverse IMRT plan was also made using Tomotherapy Hi-Art System, version 2.0, and using the same targets and optimization goals. Statistical analysis was performed by a paired t test.
RESULTS: All tomotherapy plans compared favorably with the step-and-shoot plans regarding sparing of the organs at risk and keeping an equivalent target dose homogeneity. Tomotherapy plans in particular realized sharper dose gradients compared with the step-and-shoot plans. The mean dose to all parotid glands (n = 10) decreased on average 6.5 Gy (range, -4 to 14; p = 0.002). The theoretical reduction in normal tissue complication probabilities in favor of the tomotherapy plans depended on the parotid normal tissue complication probability model used (range, -3% to 32%).
CONCLUSION: Helical tomotherapy IMRT plans realized sharper dose gradients compared with the clinically applied step-and shoot plans. They are expected to be able to reduce the parotid normal tissue complication probability further, keeping a similar target dose homogeneity.

Entities:  

Mesh:

Year:  2005        PMID: 15925457     DOI: 10.1016/j.ijrobp.2005.04.011

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  27 in total

1.  Comparative analysis of SmartArc-based dual arc volumetric-modulated arc radiotherapy (VMAT) versus intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma.

Authors:  Tsair-Fwu Lee; Pei-Ju Chao; Hui-Min Ting; Su-Hua Lo; Yu-Wen Wang; Chiu-Ching Tuan; Fu-Min Fang; Te-Jen Su
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

Review 2.  Volumetric modulated arc therapy: a review of current literature and clinical use in practice.

Authors:  M Teoh; C H Clark; K Wood; S Whitaker; A Nisbet
Journal:  Br J Radiol       Date:  2011-11       Impact factor: 3.039

3.  Dosimetric and radiobiological comparison of helical tomotherapy, forward-planned intensity-modulated radiotherapy and two-phase conformal plans for radical radiotherapy treatment of head and neck squamous cell carcinomas.

Authors:  S Chatterjee; N Willis; S M Locks; J H Mott; C G Kelly
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

4.  On Voxel based Iso-Tumor Control Probabilty and Iso-Complication Maps for Selective Boosting and Selective Avoidance Intensity Modulated Radiotherapy.

Authors:  Yusung Kim; Wolfgang A Tomé
Journal:  Imaging Decis (Berl)       Date:  2008

5.  Validation of an updated evidence-based protocol for proactive gastrostomy tube insertion in patients with head and neck cancer.

Authors:  T E Brown; V Getliffe; M D Banks; B G M Hughes; C Y Lin; L M Kenny; J D Bauer
Journal:  Eur J Clin Nutr       Date:  2016-02-10       Impact factor: 4.016

6.  The potential of helical tomotherapy in the treatment of head and neck cancer.

Authors:  Dirk Van Gestel; Dirk Verellen; Lien Van De Voorde; Bie de Ost; Geert De Kerf; Olivier Vanderveken; Carl Van Laer; Danielle Van den Weyngaert; Jan B Vermorken; Vincent Gregoire
Journal:  Oncologist       Date:  2013-05-30

7.  Image-guided Radiotherapy Of Esophageal Cancer By Helical Tomotherapy: Acute Toxicity And Preliminary Clinical Outcome.

Authors:  Yi-Jen Chen; Kemp H Kernstine; Stephen Shibata; Dean Lim; David D Smith; Martin Tang; An Liu; Richard D Pezner; Jeffrey Y C Wong
Journal:  J Thorac Dis       Date:  2009-12       Impact factor: 2.895

8.  Hippocampal-sparing whole-brain radiotherapy: a "how-to" technique using helical tomotherapy and linear accelerator-based intensity-modulated radiotherapy.

Authors:  Vinai Gondi; Ranjini Tolakanahalli; Minesh P Mehta; Dinesh Tewatia; Howard Rowley; John S Kuo; Deepak Khuntia; Wolfgang A Tomé
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-11-15       Impact factor: 7.038

9.  Helical tomotherapy for single and multiple liver tumours.

Authors:  Tsair-Fwu Lee; Pei-Ju Chao; Fu-Min Fang; Te-Jen Su; Stephen W Leung; Hsuan-Chih Hsu
Journal:  Radiat Oncol       Date:  2010-06-24       Impact factor: 3.481

10.  Recent advances in image-guided radiotherapy for head and neck carcinoma.

Authors:  Sameer K Nath; Daniel R Simpson; Brent S Rose; Ajay P Sandhu
Journal:  J Oncol       Date:  2009-07-29       Impact factor: 4.375

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.