Literature DB >> 15925241

Determination of hydroquinone in cosmetic emulsion using microdialysis sampling coupled with high-performance liquid chromatography.

Cheng-Hui Lin1, Jeun-Yuan Sheu, Hsin-Lung Wu, Yeou-Lih Huang.   

Abstract

A method based on microdialysis sampling combined with high-performance liquid chromatography (HPLC) has been developed for the determination of hydroquinone in cosmetic emulsion. In microdialysis sampling, using deionized water as perfusate, a probe length of 10mm and dialysis flow-rate of 5 microl min(-1) were found to be the optimum conditions for the analysis. The accuracy (% bias) for intra-day (n=3) and inter-day (n=12, four consecutive days) ranged from -9.5 to 13.0% with a precision less than 7.55% relative standard deviation (R.S.D.). Recovery obtained between 89 and 112% by adding hydroquinone standards into medicated cosmetics and the coefficients of variance between 0.5 and 3.3%. The linearity of calibration curve is in the range of 2 microM-2 mM with an R(2) value for the linear regression of 0.9981. The detection limit is 0.2 microM derived from the three times of signal-to-noise ratio. This method has been applied to determine the hydroquinone content in medicated and non-medicated cosmetics. The contents of hydroquinone in the medicated cosmetics are 5.36% (0.12% R.S.D., n=3) and 3.85% (0.26% R.S.D., n=3), respectively; in contrast to the percentages given by the manufacturer are 5 and 4%, the accuracy (% bias) are 7.20 and 3.75%, respectively. No hydroquinone was detected in non-medicated cosmetics. The proposed method has the advantages of easy sample pretreatment, rapid isolation and lower organic solvent consumption than in other methods for the determination of hydroquinone in cosmetics.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15925241     DOI: 10.1016/j.jpba.2005.01.031

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  4 in total

1.  Sensitive Detection of Industrial Pollutants Using Modified Electrochemical Platforms.

Authors:  Alessio Di Tinno; Rocco Cancelliere; Pietro Mantegazza; Antonino Cataldo; Alesia Paddubskaya; Luigi Ferrigno; Polina Kuzhir; Sergey Maksimenko; Mikhail Shuba; Antonio Maffucci; Stefano Bellucci; Laura Micheli
Journal:  Nanomaterials (Basel)       Date:  2022-05-23       Impact factor: 5.719

2.  One A3B Porphyrin Structure-Three Successful Applications.

Authors:  Ion Fratilescu; Anca Lascu; Bogdan Ovidiu Taranu; Camelia Epuran; Mihaela Birdeanu; Ana-Maria Macsim; Eugenia Tanasa; Eugeniu Vasile; Eugenia Fagadar-Cosma
Journal:  Nanomaterials (Basel)       Date:  2022-06-05       Impact factor: 5.719

3.  Electrochemical determination of hydroquinone using hydrophobic ionic liquid-type carbon paste electrodes.

Authors:  Yiyi She; Yougen Tang; Hongtao Liu; Ping He
Journal:  Chem Cent J       Date:  2010-10-26       Impact factor: 4.215

4.  Fabrication of an Extremely Cheap Poly(3,4-ethylenedioxythiophene) Modified Pencil Lead Electrode for Effective Hydroquinone Sensing.

Authors:  Jian-Yu Lu; Yu-Sheng Yu; Tung-Bo Chen; Chiung-Fen Chang; Sigitas Tamulevičius; Donats Erts; Kevin C-W Wu; Yesong Gu
Journal:  Polymers (Basel)       Date:  2021-01-22       Impact factor: 4.329

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.