Literature DB >> 15921948

Swirling flow pattern in a non-planar model of an interposition vein cuff anastomosis.

T V How1, R K Fisher, J A Brennan, P L Harris.   

Abstract

One of the main causes of long-term failure of ePTFE grafts is the development of anastomotic intimal hyperplasia which leads to graft thrombosis. Experimental studies with bypass grafts have shown an inverse relationship between mean wall shear stress and intimal hyperplasia. The geometry of the anastomosis has a strong influence on the flow pattern and wall shear stress distribution. The aim of this in vitro study was to investigate the influence of non-planarity in a model of a distal anastomosis with interposition vein cuff, an anastomosis configuration that is increasingly being used because of improved clinical results. Laser Doppler anemometer measurements were carried out in silicone rubber models of interposition vein cuff anastomoses with planar and non-planar inflow. The pulsatile flow waveforms were typical of those found in femoro-infrapopliteal bypass. Axial and radial velocities were measured in the proximal and distal outflow segments. As expected a symmetrical helical flow pattern (Dean flow) was evident in the planar model. The model with non-planar inflow, however, gave rise to swirling flow in both the distal and proximal artery outflow segments for during the systolic phase. In patients, the anastomosis is usually non-planar. Since the configuration depends in part upon the tunnelling of the graft, this may be altered to some extent. Non-planar anastomotic configurations induce a swirling flow pattern, which may normalise wall shear stress, thereby potentially reducing intimal hyperplasia.

Entities:  

Mesh:

Year:  2006        PMID: 15921948     DOI: 10.1016/j.medengphy.2005.04.016

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  2 in total

1.  Intimal hyperplasia following implantation of helical-centreline and straight-centreline stents in common carotid arteries in healthy pigs: influence of intraluminal flow.

Authors:  Colin Gerald Caro; Anusha Seneviratne; Kevin B Heraty; Claudia Monaco; Martin G Burke; Rob Krams; Carlos C Chang; Paul Gilson; Gianfilippo Coppola
Journal:  J R Soc Interface       Date:  2013-10-16       Impact factor: 4.118

Review 2.  Swirling Flow and Wall Shear: Evaluating the BioMimics 3D Helical Centerline Stent for the Femoropopliteal Segment.

Authors:  Timothy M Sullivan; Thomas Zeller; Masato Nakamura; Colin G Caro; Michael Lichtenberg
Journal:  Int J Vasc Med       Date:  2018-02-26
  2 in total