Literature DB >> 15919331

Sutureless repair with TachoComb sheets for oozing type postinfarction cardiac rupture.

Akihito Muto1, Toshiya Nishibe, Yuka Kondo, Masato Sato, Mituru Yamashita, Motomi Ando.   

Abstract

Left ventricular free-wall rupture is a well recognized complication of myocardial infarction and a frequent cause of death. The appropriate surgical management varies significantly depending on the condition of the tear and the presence of concomitant lesions. We present a case of oozing type postinfarction cardiac rupture that was treated successfully by a sutureless patch technique using a fibrin tissue-adhesive collagen fleece (TachoComb [Torii Pharmaceutical, Tokyo, Japan]). This represents a quick, effective, and safe option for dealing with oozing type myocardial rupture due to myocardial infarction.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15919331     DOI: 10.1016/j.athoracsur.2003.12.033

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  11 in total

Review 1.  Sutureless repair techniques for post-infarction left ventricular free wall rupture.

Authors:  Homare Okamura
Journal:  Ann Cardiothorac Surg       Date:  2022-05

2.  Early pseudoaneurysm formation after the sutureless technique for left ventricular rupture due to acute myocardial infarction.

Authors:  Kenichi Sasaki; Toshihiro Fukui; Minoru Tabata; Shuichiro Takanashi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-03-26

3.  Delayed Cardiac Rupture Induced by Traumatic Myocardial Infarction: Consequence of a 45-Magnum Blast Injury; A Comprehensive Case Review.

Authors:  Holger Rupprecht; Katharina Gaab
Journal:  Bull Emerg Trauma       Date:  2018-01

4.  Idiopathic Spinal Cord Herniation Presented as Brown-Sequard Syndrome : A Case Report and Surgical Outcome.

Authors:  Min-Wook Ju; Seung-Won Choi; Jin-Young Youm; Hyon-Jo Kwon
Journal:  J Korean Neurosurg Soc       Date:  2015-09-30

5.  Patch-and-glue repair in combination with or without direct suture for cardiac rupture after myocardial infarction.

Authors:  Toshihiro Fujimatsu; Hajime Oosawa; Fumie Takai; Masakazu Aruga; Fumiaki Ogiwara; Eiichiro Mawatari; Shunpei Sakurai
Journal:  Gen Thorac Cardiovasc Surg       Date:  2007-09

6.  Repair of ventricle free wall rupture after acute myocardial infarction: a case report.

Authors:  Hasan Ekim; Mustafa Tuncer; Halil Basel
Journal:  Cases J       Date:  2009-11-27

7.  Repair of Post-Infarction Ventricular Free Wall Rupture With TachoSil(®).

Authors:  Maziar Gholampour-Dehaki; Hoda Javadikasgari; Asghar Zare; Mohsen Madani
Journal:  Res Cardiovasc Med       Date:  2015-09-15

8.  Off-pump suture repair of left ventricular rupture utilizing TachoComb® sheet: a case report and literature review.

Authors:  Hiroki Yamaguchi; Tatsuya Nakao; Noriyuki Tokunaga; Hiromasa Nakamura; Masami Takagaki
Journal:  World J Emerg Surg       Date:  2013-07-27       Impact factor: 5.469

9.  Polyglycolic acid sheet with fibrin glue potentiates the effect of a fibrin-based haemostat in cardiac surgery.

Authors:  Hirofumi Kasahara; Ichiro Hayashi
Journal:  J Cardiothorac Surg       Date:  2014-07-08       Impact factor: 1.637

10.  A new hybrid sutureless patch repair utilizing chitosan for left ventricle rupture after myocardial infarction: A case report.

Authors:  Yoshihisa Morimoto; Takaki Sugimoto; Fumiya Haba; Hideki Sakahira
Journal:  Int J Surg Case Rep       Date:  2016-07-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.