Literature DB >> 15915347

Critical review of the application of liquid chromatography/mass spectrometry to the determination of pesticide residues in biological samples.

F Hernández1, J V Sancho, O J Pozo.   

Abstract

A critical review is made on the use of hyphenated liquid chromatography/mass spectrometry (LC-MS) for the identification and quantification of pesticides and their metabolites in human biosamples (whole blood, plasma, serum and urine). The first applications of LC-MS in this field began in the early 1990s. Since then, increasing interest has been shown in applying this powerful technique, with most applications dealing with the determination of a variety of chemically diverse metabolites in urine. The use of different LC-MS interfaces and mass spectral detection modes are discussed. Special attention is given to tandem mass spectrometry (MS/MS) due to its inherent advantages of increased sensitivity and selectivity, as well as its advantages for identification and confirmation of analytes in samples. Quantification can be severely affected by matrix effects, the most common being inhibition of the ionisation of analytes in the mass spectrometer, which leads to unacceptable errors if no correction is made. Different approaches can be employed to minimise this undesirable matrix effect, the preferred being the use of labelled internal standards (when available) in isotope dilution methods or the application of an efficient clean-up, performed off-line or automated on-line. Adequate criteria for confirming the identities of residues detected are required in order to avoid false positives. The criterion most commonly used with a triple quadrupole instrument is the monitoring of two MS/MS transitions together with the ion abundance ratio. TOF mass analysers are seldom used in pesticide residue analysis despite their improved resolution and mass accuracy characteristics, which makes them very suitable for confirmation purposes. The main reasons for the relative unpopularity of TOF MS in residue analysis are its limited sensitivity and its high acquisition cost. In this paper, we present a critical assessment on current techniques, trends and future developments, and give illustrative examples to point out the main characteristics of LC-MS for pesticide residue analysis in biological fluids.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15915347     DOI: 10.1007/s00216-005-3185-5

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  13 in total

Review 1.  Occurrence of PPCPs in the marine environment: a review.

Authors:  Lauren Arpin-Pont; Maria Jesus Martinez Bueno; Elena Gomez; Hélène Fenet
Journal:  Environ Sci Pollut Res Int       Date:  2014-09-26       Impact factor: 4.223

2.  Accurate determination of tissue steroid hormones, precursors and conjugates in adult male rat.

Authors:  Naoyuki Maeda; Emi Tanaka; Tomokazu Suzuki; Kanako Okumura; Sachiko Nomura; Taku Miyasho; Satoko Haeno; Hiroshi Yokota
Journal:  J Biochem       Date:  2012-10-10       Impact factor: 3.387

Review 3.  Analysis of mobile chemicals in the aquatic environment-current capabilities, limitations and future perspectives.

Authors:  Daniel Zahn; Isabelle J Neuwald; Thomas P Knepper
Journal:  Anal Bioanal Chem       Date:  2020-02-21       Impact factor: 4.142

4.  A sensitive magnetic nanoparticle-based immunoassay of phosphorylated acetylcholinesterase using protein cage templated lead phosphate for signal amplification with graphite furnace atomic absorption spectrometry detection.

Authors:  Pei Liang; Caiyan Kang; Enjian Yang; Xiaoxiao Ge; Dan Du; Yuehe Lin
Journal:  Analyst       Date:  2016-04-07       Impact factor: 4.616

5.  Biomonitoring of organophosphorus agent exposure by reactivation of cholinesterase enzyme based on carbon nanotube-enhanced flow-injection amperometric detection.

Authors:  Dan Du; Jun Wang; Jordan N Smith; Charles Timchalk; Yuehe Lin
Journal:  Anal Chem       Date:  2009-11-15       Impact factor: 6.986

6.  Characterization of endocrine disruptors from a complex matrix using estrogen receptor affinity columns and high performance liquid chromatography-high resolution mass spectrometry.

Authors:  Adeline Jondeau-Cabaton; Amélie Soucasse; Emilien L Jamin; Nicolas Creusot; Marina Grimaldi; Isabelle Jouanin; Sélim Aït-Aïssa; Patrick Balaguer; Laurent Debrauwer; Daniel Zalko
Journal:  Environ Sci Pollut Res Int       Date:  2013-01-15       Impact factor: 4.223

7.  Attomolar SERS detection of organophosphorous pesticides using silver mirror-like micro-pyramids as active substrate.

Authors:  Marta Lafuente; Erwin J W Berenschot; Roald M Tiggelaar; Sergio G Rodrigo; Reyes Mallada; Niels R Tas; María P Pina
Journal:  Mikrochim Acta       Date:  2020-03-26       Impact factor: 5.833

Review 8.  Good quantification practices of flavours and fragrances by mass spectrometry.

Authors:  Frédéric Begnaud; Alain Chaintreau
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2016-10-28       Impact factor: 4.226

Review 9.  Human biological monitoring of suspected endocrine-disrupting compounds.

Authors:  Moosa Faniband; Christian H Lindh; Bo A G Jönsson
Journal:  Asian J Androl       Date:  2014 Jan-Feb       Impact factor: 3.285

Review 10.  Bridging Targeted and Untargeted Mass Spectrometry-Based Metabolomics via Hybrid Approaches.

Authors:  Li Chen; Fanyi Zhong; Jiangjiang Zhu
Journal:  Metabolites       Date:  2020-08-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.