Literature DB >> 15915264

Improving agglutination tests by working in microfluidic channels.

G Degré1, E Brunet, A Dodge, P Tabeling.   

Abstract

Latex agglutination tests are used for the diagnosis of diseases in man and animals. They are generally simple, cheap, and do not require sophisticated equipment, nor highly specialized skills. In this Technical Note, we put latex agglutination tests in a microfluidic format. The experiment is performed in PDMS (polydimethylsiloxane) microchannels, using streptavidin-coated superparamagnetic beads and a magnetic field. The target molecule is biotinylated protein A. By taking full advantage of the microfluidic conditions (scaling down of the detection volume and controlled action of the shear flow), we achieved an analytical sensitivity of 10 fmol l(-1)(several hundreds of fg ml(-1)) and a fast response (a few minutes) ; the test is also quantitative. Performances of agglutination tests can thus be improved by orders of magnitude by adapting them to a microfluidic format; this comes in addition to the usual advantages offered by this technology (integration, high throughput etc.).

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15915264     DOI: 10.1039/b501695a

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  5 in total

1.  Homogeneous agglutination assay based on micro-chip sheathless flow cytometry.

Authors:  Zengshuai Ma; Pan Zhang; Yinuo Cheng; Shuai Xie; Shuai Zhang; Xiongying Ye
Journal:  Biomicrofluidics       Date:  2015-12-01       Impact factor: 2.800

2.  On-chip immuno-agglutination assay based on a dynamic magnetic bead clump and a sheath-less flow cytometry.

Authors:  Shuai Zhang; Zengshuai Ma; Yushu Zhang; Yue Wang; Yinuo Cheng; Wenhui Wang; Xiongying Ye
Journal:  Biomicrofluidics       Date:  2019-07-11       Impact factor: 2.800

3.  On-chip immunoassay for determination of urinary albumin.

Authors:  Wanida Laiwattanapaisal; Temsiri Songjaroen; Thitima Maturos; Tanom Lomas; Assawapong Sappat; Adisorn Tuantranont
Journal:  Sensors (Basel)       Date:  2009-12-10       Impact factor: 3.576

4.  Magnetic Particle Plug-Based Assays for Biomarker Analysis.

Authors:  Chayakom Phurimsak; Mark D Tarn; Nicole Pamme
Journal:  Micromachines (Basel)       Date:  2016-04-26       Impact factor: 2.891

5.  High-Throughput Incubation and Quantification of Agglutination Assays in a Microfluidic System.

Authors:  David Castro; David Conchouso; Rimantas Kodzius; Arpys Arevalo; Ian G Foulds
Journal:  Genes (Basel)       Date:  2018-06-04       Impact factor: 4.096

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.