Literature DB >> 15914947

Novel Doppler technique to assess systemic vascular resistance: the snuffbox technique.

Koji Ban1, Kazuhiro Kochi, Katsuhiko Imai, Kenji Okada, Kazumasa Orihashi, Taijiro Sueda.   

Abstract

BACKGROUND: To explore an alternative to the systemic vascular resistance index (SVRI) for monitoring peripheral circulation in patients in the intensive care unit (ICU), the resistive index (RI) in the upper extremity arteries was measured by using surface Doppler ultrasound. METHODS AND
RESULTS: The correlation between RI and vascular resistance was assessed in vitro using a vessel phantom in a Donovan-type mock circulation system. In addition, 15 ICU patients who had undergone open-heart surgery were studied. Mean arterial pressure, central venous pressure and cardiac output were measured 30 times at 10 min intervals after patients returned to the ICU following surgery, and the SVRI was calculated from these parameters. At the same time points, 3 parts of the upper extremity arteries (brachial artery in the cubital fossa (BA), radial artery at the wrist (RA), and radial artery at the anatomical snuffbox (SB)) were scanned by Doppler ultrasound, and the resistance index (RI) for each artery region was calculated. In vitro, RI increased with higher vascular resistance, exhibiting a significant correlation (r = 0.982, p < 0.0001). In vivo, the average incidence angles at the BA and RA were larger than 60 degrees , while that at the SB was only 11.5+/-10.8 degrees. The overall correlation between SVRI and RI for all patients was not significant for the BA or RA, but was significant for the SB (p < 0.0001). In individual patients, the correlation of SVRI with RI at the BA or RA was significant in 3 patients only, whereas significant correlation for the SB was observed in all patients. Doppler waveform analysis at the SB revealed diastolic flow reversal with increased SVRI.
CONCLUSIONS: Measurement at the SB provides an ideal ultrasound incidence angle for the measurement of blood flow velocity. Hence, RI measured in this way may serve as an indicator of peripheral vascular resistance, and may be effective for the evaluation of peripheral circulatory disturbance.

Entities:  

Mesh:

Year:  2005        PMID: 15914947     DOI: 10.1253/circj.69.688

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  3 in total

1.  Effects of medetomidine-midazolam-fentanyl IV bolus injections and its reversal by specific antagonists on cardiovascular function in rabbits.

Authors:  Christine Baumgartner; Melanie Bollerhey; Johanna Ebner; Tibor Schuster; Julia Henke; Wolf Erhardt
Journal:  Can J Vet Res       Date:  2010-10       Impact factor: 1.310

2.  Effects of ketamine-xylazine intravenous bolus injection on cardiovascular function in rabbits.

Authors:  Christine Baumgartner; Melanie Bollerhey; Johanna Ebner; Lién Laacke-Singer; Tibor Schuster; Wolf Erhardt
Journal:  Can J Vet Res       Date:  2010-07       Impact factor: 1.310

3.  USER Protocol as a Guide to Resuscitation of the Patient with Septic Shock in the Emergency Department.

Authors:  German Devia Jaramillo; Salvador Menendez Ramirez
Journal:  Open Access Emerg Med       Date:  2021-02-12
  3 in total