Literature DB >> 15913140

Flow-through chloroquine sensor and its applications in pharmaceutical analysis.

Bahruddin Saad1, Zainiharyati Mohd Zin, Md Sariff Jab, Ismail Ab Rahman, Muhammad Idiris Saleh, Shariff Mahsufi.   

Abstract

Poly (vinyl chloride) membrane electrodes that responded selectively towards the antimalarial drug chloroquine are described. The electrodes were based on the use of the lipophilic potassium tetrakis(4-chlorophenyl)borate as ion-exchanger and bis(2-ethylhexyl)adipate (BEHA), or trioctylphosphate (TOP) or dioctylphenylphosphonate (DOPP) as plasticizing solvent mediator. All electrodes produced good quality characteristics such as Nernstian- and rapid responses, and are minimally interfered with by the alkali and alkaline earth metal ions tested. The membranes were next applied to a flow-through device, enabling it to function as flow-injection analysis (FIA) detector. The performance of the sensor after undergoing the FIA optimization was further evaluated for its selectivity characteristics and lifetime. Results for the determination of chloroquine in synthetic samples that contained common tablet excipients such as glucose, starch, and cellulose, and other foreign species such as cations, citric acid or lactic acid were generally satisfactory. The sensor was also successfully used for the determination of the active ingredients in mock tablets, synthetic fluids and biological fluids. The sensor was applied for the determination of active ingredients and the dissolution profile of commercial tablets was also established.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15913140     DOI: 10.2116/analsci.21.521

Source DB:  PubMed          Journal:  Anal Sci        ISSN: 0910-6340            Impact factor:   2.081


  4 in total

1.  Voltammetric determination of the antimalarial drug chloroquine using a glassy carbon electrode modified with reduced graphene oxide on WS2 quantum dots.

Authors:  Monika Srivastava; Preeti Tiwari; Vineet Kumar Mall; S K Srivastava; Rajiv Prakash
Journal:  Mikrochim Acta       Date:  2019-06-11       Impact factor: 5.833

Review 2.  Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade.

Authors:  Farnoush Faridbod; Parviz Norouzi; Rassoul Dinarvand; Mohammad Reza Ganjali
Journal:  Sensors (Basel)       Date:  2008-04-03       Impact factor: 3.576

3.  Ionophore-based potentiometric sensors for the flow-injection determination of promethazine hydrochloride in pharmaceutical formulations and human urine.

Authors:  Ahmed Khudhair Hassan; Bahruddin Saad; Sulaiman Ab Ghani; Rohana Adnan; Afidah Abdul Rahim; Norariza Ahmad; Marina Mokhtar; Suham Tawfiq Ameen; Suad Mustafa Al-Araji
Journal:  Sensors (Basel)       Date:  2011-01-18       Impact factor: 3.576

4.  Development and evaluation of Pleurotus tuber-regium-cornstarch composite as a direct compression multifunctional excipient.

Authors:  Ebere I Okoye; Anthony O Onyekweli
Journal:  Int J Pharm Investig       Date:  2016 Jan-Mar
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.