Literature DB >> 15912729

Solid phase micro-extraction coupled with ion mobility spectrometry for the analysis of ephedrine in urine.

John K Lokhnauth1, Nicholas H Snow.   

Abstract

Quantitative solid phase micro-extraction (SPME) coupled with ion mobility spectrometry is demonstrated using the analysis of ephedrine in urine. Since its inception in the 1970's ion mobility spectrometry (IMS) has evolved into a useful technique for laboratories to detect explosives, chemical warfare agents, environment pollutants and, increasingly, for detecting drugs of abuse. Ephedrine is extracted directly from urine samples using SPME and the analyte on the fiber is heated by the IMS desorber unit and vaporized into the drift tube. The analytical procedure was optimized for fiber coating selection, extraction temperature, extraction time, sample pH, and analyte desorption temperature. The carryover effects, ion fragmentation characteristics, peak shapes, and drift times of ephedrine were also evaluated based on the direct interfacing of SPME to IMS. A limit of detection of 50 ng/mL of ephedrine in urine and a linear range of 3 orders of magnitude were obtained, showing that SPME-IMS compares well to other techniques for ephedrine and drug analysis presented in the literature.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15912729     DOI: 10.1002/jssc.200401924

Source DB:  PubMed          Journal:  J Sep Sci        ISSN: 1615-9306            Impact factor:   3.645


  4 in total

1.  Low invasive in vivo tissue sampling for monitoring biomarkers and drugs during surgery.

Authors:  Barbara Bojko; Krzysztof Gorynski; German A Gomez-Rios; Jan M Knaak; Tiago Machuca; Erasmus Cudjoe; Vinzent N Spetzler; Michael Hsin; Marcelo Cypel; Markus Selzner; Mingyao Liu; Shaf Keshjavee; Janusz Pawliszyn
Journal:  Lab Invest       Date:  2014-03-31       Impact factor: 5.662

Review 2.  Review on ion mobility spectrometry. Part 1: current instrumentation.

Authors:  R Cumeras; E Figueras; C E Davis; J I Baumbach; I Gràcia
Journal:  Analyst       Date:  2015-03-07       Impact factor: 4.616

3.  Portable solid phase micro-extraction coupled with ion mobility spectrometry system for on-site analysis of chemical warfare agents and simulants in water samples.

Authors:  Liu Yang; Qiang Han; Shuya Cao; Jie Yang; Junchao Yang; Mingyu Ding
Journal:  Sensors (Basel)       Date:  2014-11-06       Impact factor: 3.576

4.  Rapid Detection of Six Glucocorticoids Added Illegally to Dietary Supplements by Combining TLC with Spot-Concentrated Raman Scattering.

Authors:  Li Li; Xin Liang; Tao Xu; Feng Xu; Wei Dong
Journal:  Molecules       Date:  2018-06-21       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.