Literature DB >> 15912469

Development of a rapid and specific assay for detection of busulfan in human plasma by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry.

Ederson Oliveira dos Reis1, Rosane Vianna-Jorge, Guilherme Suarez-Kurtz, Edson Luiz da Silva Lima, Débora de Almeida Azevedo.   

Abstract

A sensitive and specific assay for detection of busulfan in human plasma was developed. The assay is based on rapid isolation of busulfan by liquid-liquid extraction with ethyl acetate, and detection by high-performance liquid chromatography with electrospray ionization and tandem mass spectrometry. 1,6-Bis(methanesulfonyloxy)hexane, a synthesized analogue of busulfan, was used as the internal standard (IS). The acquisition was performed in the multiple reaction monitoring mode; busulfan and the IS were detected with no interferences from plasma matrix. The method was linear over the range 5-2500 ng mL(-1), with r2 > 0.99 and a run time of only 3.5 min. The intra- and inter-assay precisions were in the ranges 2.1-11.9% and 3.2-10.1%, respectively, and the intra- and inter-assay accuracies were 92.2-107.6% and 94.7-104.1%, respectively. The absolute recoveries were 82.0% (20 ng mL(-1)), 90.6% (1000 ng mL(-1)) and 80.0% (2000 ng mL(-1)) for busulfan, and 89.1% for the IS (1000 ng mL(-1)). The limits of detection and quantification were 2 and 5 ng mL(-1), respectively. The validated method was successfully applied to analyze plasma samples obtained from six adults receiving doses of 1 mg kg(-1) in a conditioning regimen prior to bone marrow transplantation. A marked intra-patient variation in busulfan concentrations during the steady state was observed, which limits the application of pharmacokinetic modeling and suggests that continuous therapeutic monitoring is necessary for adequate individualized dosing. In this regard, the present assay brings important advantages relative to other methods described in the literature, i.e., it is highly specific and simple to perform, with a rapid chromatographic run time (3.5 min), and the whole procedure can be completed in 4-5 h, which would permit dose corrections after the third dose allowing earlier and better dosing adjustments towards the target level of busulfan. Copyright 2005 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15912469     DOI: 10.1002/rcm.1962

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  6 in total

1.  Busulfan dosing algorithm and sampling strategy in stem cell transplantation patients.

Authors:  Francine A de Castro; Chiara Piana; Belinda P Simões; Vera L Lanchote; O Della Pasqua
Journal:  Br J Clin Pharmacol       Date:  2015-07-22       Impact factor: 4.335

2.  Mini test dose of intravenous busulfan (busulfex(®)) in allogeneic non-myeloablative stem cell transplantation, followed by liquid chromatography tandem-mass spectrometry.

Authors:  Ivan Spasojevic; Ligia R S da Costa; Mitchell E Horwitz; Gwynn D Long; Keith M Sullivan; John P Chute; Cristina Gasparetto; Ashley Morris; Nelson J Chao; David A Rizzieri
Journal:  Cancer Invest       Date:  2012-09-28       Impact factor: 2.176

3.  Should busulfan therapeutic range be narrowed in pediatrics? Experience from a large cohort of hematopoietic stem cell transplant children.

Authors:  M Philippe; S Goutelle; J Guitton; X Fonrose; C Bergeron; P Girard; Y Bertrand; N Bleyzac
Journal:  Bone Marrow Transplant       Date:  2015-09-21       Impact factor: 5.483

4.  Accurately Achieving Target Busulfan Exposure in Children and Adolescents With Very Limited Sampling and the BestDose Software.

Authors:  Michael Neely; Michael Philippe; Teresa Rushing; Xiaowei Fu; Michael van Guilder; David Bayard; Alan Schumitzky; Nathalie Bleyzac; Sylvain Goutelle
Journal:  Ther Drug Monit       Date:  2016-06       Impact factor: 3.681

5.  A simple dosing scheme for intravenous busulfan based on retrospective population pharmacokinetic analysis in korean patients.

Authors:  Sangmin Choe; Gayeong Kim; Hyeong-Seok Lim; Sang-Heon Cho; Jong-Lyul Ghim; Jin Ah Jung; Un-Jib Kim; Gyujeong Noh; Kyun-Seop Bae; Dongho Lee
Journal:  Korean J Physiol Pharmacol       Date:  2012-08-10       Impact factor: 2.016

6.  Quantification of human plasma-busulfan concentration by liquid chromatography-tandem mass spectrometry.

Authors:  Soo Young Moon; Min Kyoo Lim; Susie Hong; Yongbum Jeon; Minje Han; Sang Hoon Song; Kyoung Soo Lim; Kyung-Sang Yu; In-Jin Jang; Ji Won Lee; Hyoung Jin Kang; Junghan Song
Journal:  Ann Lab Med       Date:  2013-12-06       Impact factor: 3.464

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.