Literature DB >> 1591203

Corneal light scattering after excimer laser photorefractive keratectomy: the objective measurements of haze.

C P Lohmann1, G T Timberlake, F W Fitzke, D S Gartry, M K Muir, J Marshall.   

Abstract

BACKGROUND: After photorefractive keratectomy using excimer lasers (193 nm), most corneas show a marginal loss of transparency (haze) and the assessment of its magnitude in clinical studies has been subjective. To address this problem, we have developed a new device for the objective measurement of haze by measuring corneal light scattering.
METHODS: A CCD-camera was fixed at 40 degrees to a slit-lamp microscope and connected via frame-grabber to a computer. By incorporating polarizing filters, the system could discriminate between reflected and scattered light. The intensity of light coming from the cornea was measured in gray scale levels using in-house image analysis software. The system was calibrated against three different sizes of microspheres (0.25, 0.50, and 5.00 microns) which corresponded to the size of cellular and extracellular elements known to occur at sites of corneal surgery. Data were obtained from three treated human eyes with measurements before treatment and at five different postoperative intervals with a maximum follow up of 4 months.
RESULTS: All three sizes of microspheres caused disturbances in gray scale levels (36 to 255 units) in the same range of those observed in corneal measurements. Disturbances in corneal light scattering were noted from 1 week postoperatively and persisted throughout the period of observation. We observed an increase in reflected and scattered light until the 2nd postoperative month followed by a subsequent decline.
CONCLUSIONS: It appears that this device is very useful to defect and measure objectively disturbances in corneal transparency after excimer laser photorefractive keratectomy.

Entities:  

Mesh:

Year:  1992        PMID: 1591203

Source DB:  PubMed          Journal:  Refract Corneal Surg        ISSN: 1042-962X


  11 in total

Review 1.  In vivo confocal microscopy of the human cornea.

Authors:  I Jalbert; F Stapleton; E Papas; D F Sweeney; M Coroneo
Journal:  Br J Ophthalmol       Date:  2003-02       Impact factor: 4.638

2.  Corneal wound healing after photorefractive keratectomy: a 3-year confocal microscopy study.

Authors:  Jay C Erie
Journal:  Trans Am Ophthalmol Soc       Date:  2003

3.  Effect of ablation profile on wound healing and visual performance 1 year after excimer laser photorefractive keratectomy.

Authors:  M C Corbett; S Verma; D P O'Brart; K M Oliver; G Heacock; J Marshall
Journal:  Br J Ophthalmol       Date:  1996-03       Impact factor: 4.638

4.  Wound healing anomalies after excimer laser photorefractive keratectomy: correlation of clinical outcomes, corneal topography, and confocal microscopy.

Authors:  R F Steinert
Journal:  Trans Am Ophthalmol Soc       Date:  1997

5.  Effect of beam variables on corneal sensitivity after excimer laser photorefractive keratectomy.

Authors:  J G Lawrenson; M C Corbett; D P O'Brart; J Marshall
Journal:  Br J Ophthalmol       Date:  1997-08       Impact factor: 4.638

6.  Glare sensitivity and visual acuity after excimer laser photorefractive keratectomy for myopia.

Authors:  U Niesen; U Businger; P Hartmann; P Senn; I Schipper
Journal:  Br J Ophthalmol       Date:  1997-02       Impact factor: 4.638

7.  Stray light in photorefractive keratectomy for myopia.

Authors:  H G Veraart; T J van den Berg; R Hennekes; A M Adank
Journal:  Doc Ophthalmol       Date:  1995       Impact factor: 2.379

8.  Identical excimer laser PTK treatments in rabbits result in two distinct haze responses.

Authors:  Russell L McCally; Patrick J Connolly; Walter J Stark; Sandeep Jain; Dimitri T Azar
Journal:  Invest Ophthalmol Vis Sci       Date:  2006-10       Impact factor: 4.799

9.  The effect of corneal light scatter on vision after penetrating keratoplasty.

Authors:  Sanjay V Patel; Jay W McLaren; David O Hodge; William M Bourne
Journal:  Am J Ophthalmol       Date:  2008-09-06       Impact factor: 5.258

Review 10.  Corneal structure and transparency.

Authors:  Keith M Meek; Carlo Knupp
Journal:  Prog Retin Eye Res       Date:  2015-07-02       Impact factor: 21.198

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.