Literature DB >> 15910476

Canal preparation with Hero 642 rotary Ni-Ti instruments compared with stainless steel hand K-file assessed using computed tomography.

T Taşdemir1, H Aydemir, U Inan, O Unal.   

Abstract

AIM: To compare ex vivo root canal preparation with conventional stainless steel K-files and Hero 642 rotary Ni-Ti instruments.
METHODOLOGY: Mesiobuccal canals of 20 maxillary first molars (with angles of curvature between 25 degrees and 35 degrees ) were used. After preparation with Hero 642 rotary instruments and stainless steel K-files, the amount of transportation that occurred was assessed using computed tomography. The teeth were scanned by computed tomography before instrumentation. One millimetre thick slices were prepared from the apical end point to the pulp chamber. The first two sections were 3 mm from the apical end of the root (apical level) and 3 mm below the orifice (coronal level). A further section (mid-root level) was recorded, dividing the distance between the sections of apical and coronal levels into two equal lengths. Ten teeth were instrumented using Hero 642 rotary instruments and another 10 teeth were instrumented using stainless steel K-files. Following the completion of the instrumentation, the teeth were again scanned and compared with the cross-sectional images taken prior to canal preparation. Amount of transportation and centreing ability was assessed. Student's t-test was used for statistical analysis.
RESULTS: Less transportation occurred with Hero 642 rotary instruments than stainless steel K-files at the mid-root and coronal levels (mid-root: P < 0.05 and coronal: P < 0.001). Hero 642 rotary instruments had better centreing ability than K-files at all three levels (apical: P < 0.05, mid-root: P < 0.05 and coronal: P < 0.001).
CONCLUSIONS: Hero 642 rotary instruments transported canals less, especially at the middle and coronal thirds of the root canals than stainless steel K-files. Hero 642 instruments had better centreing ability.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15910476     DOI: 10.1111/j.1365-2591.2005.00961.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  23 in total

1.  Microcomputed tomographic analysis of the furcation grooves of maxillary first premolars.

Authors:  Saad Misfer Al-Shahrani; Dina Al-Sudani; Majed Almalik; Gianluca Gambarini; Faisal Ahmed Alrumaihi
Journal:  Ann Stomatol (Roma)       Date:  2013-03-20

2.  Assessment of the Centralization of Root Canal Preparation with Rotary Systems.

Authors:  Daniela Siqueira Lopes; Mariana Albuquerque Veiga Pessoa; Carlos Menezes Aguiar
Journal:  Acta Stomatol Croat       Date:  2016-09

3.  Analysis of kinematic, kinetic and electromyographic patterns during root canal preparation with rotary and manual instruments.

Authors:  Braulio Pasternak; Manoel Damião de Sousa Neto; Valdeci Carlos Dionísio; Jesus Djalma Pécora; Ricardo Gariba Silva
Journal:  J Appl Oral Sci       Date:  2012-02       Impact factor: 2.698

4.  CT evaluation of canal preparation using rotary and hand NI-TI instruments: An in vitro study.

Authors:  Shruthi Nagaraja; B V Sreenivasa Murthy
Journal:  J Conserv Dent       Date:  2010-01

5.  Canal-centering ability: An endodontic challenge.

Authors:  Deivanayagam Kandaswamy; Nagendrababu Venkateshbabu; Ilango Porkodi; Gali Pradeep
Journal:  J Conserv Dent       Date:  2009-01

6.  Imaging techniques in endodontics: an overview.

Authors:  B S Deepak; T S Subash; V J Narmatha; T Anamika; T K Snehil; D B Nandini
Journal:  J Clin Imaging Sci       Date:  2012-03-22

7.  Cone-beam computed tomography for evaluation of apical transportation in root canals prepared by two rotary systems.

Authors:  Zahra Sadat Madani; Azam Haddadi; Sina Haghanifar; Ali Bijani
Journal:  Iran Endod J       Date:  2014-03-08

8.  Effects of preparation techniques on root canal shaping assessed by micro-computed tomography.

Authors:  Miranda Stavileci; Veton Hoxha; Ömer Görduysus; Ilkan Tatar; Kjell Laperre; Jeroen Hostens; Selen Küçükkaya; Merita Berisha
Journal:  Med Sci Monit Basic Res       Date:  2013-06-13

9.  An ex-vivo study on the shaping parameters of two nickel-titanium rotary systems compared with hand instruments.

Authors:  Maryam Ehsani; Samir Zahedpasha; Ali Akbar Moghadamnia; Jaber Mirjani
Journal:  Iran Endod J       Date:  2011-05-15

10.  Effect of rotatory instrument speed on its capacity to remove demineralized and sound dentin.

Authors:  Mariana Cortes; Vanessa Galego Arias Pecorari; Roberta Tarkany Basting; Fabiana Mantovani Gomes França; Cecília Pedroso Turssi; Flávia Lucisano Botelho do Amaral
Journal:  Eur J Dent       Date:  2013-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.