Literature DB >> 15910351

A noninvasive estimation of mixed venous oxygen saturation using near-infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients.

Tia A Tortoriello1, Stephen A Stayer, Antonio R Mott, E Dean McKenzie, Charles D Fraser, Dean B Andropoulos, Anthony C Chang.   

Abstract

BACKGROUND: Near-infrared spectroscopy (NIRS) is a noninvasive optical monitor of regional cerebral oxygen saturation (rSO2). The aim of this study was to validate the use of NIRS by cerebral oximetry in estimating invasively measured mixed venous oxygen saturation (SvO2) in pediatric postoperative cardiac surgery patients.
METHODS: Twenty patients were enrolled following cardiac surgery with intraoperative placement of a pulmonary artery (PA) or superior vena cava (SVC) catheter. Five patients underwent complete biventricular repair--complete atrioventricular canal (n=3) and other (n=2). Fifteen patients with functional single ventricle underwent palliative procedures--bidirectional Glenn (n=11) and Fontan (n=4). Cerebral rSO2 was monitored via NIRS (INVOS 5100) during cardiac surgery and 6 h postoperatively. SvO2 was measured from blood samples obtained via an indwelling PA or SVC catheter and simultaneously correlated with rSO2 by NIRS at five time periods: in the operating room after weaning from cardiopulmonary bypass, after sternal closure, and in the CICU at 2, 4, and 6 h after admission.
RESULTS: Each patient had five measurements (total=100 comparisons). SvO2 obtained via an indwelling PA or SVC catheter for all patients correlated with rSO2 obtained via NIRS: Pearson's correlation coefficient of 0.67 (P<0.0001) and linear regression of r2=0.45 (P<0.0001). Separate linear regression of the complete biventricular repairs demonstrated an r=0.71, r2=0.50 (P<0.0001). Bland-Altman analysis showed a bias of +3.3% with a precision of 16.6% for rSO2 as a predictor of SvO2 for all patients. Cerebral rSO2 was a more accurate predictor of SvO2 in the biventricular repair patients (bias -0.3, precision 11.8%), compared with the bidirectional Glenn and Fontan patients.
CONCLUSIONS: Regional cerebral oximetry via NIRS correlates with SvO2 obtained via invasive monitoring. However, the wide limits of agreement suggest that it may not be possible to predict absolute values of SvO2 for any given patient based solely on the noninvasive measurement of rSO2. Near-infrared spectroscopy, using the INVOS 5100 cerebral oximeter, could potentially be used to indicate trends in SVO2, but more studies needs to be performed under varying clinical conditions.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15910351     DOI: 10.1111/j.1460-9592.2005.01488.x

Source DB:  PubMed          Journal:  Paediatr Anaesth        ISSN: 1155-5645            Impact factor:   2.556


  25 in total

1.  Noninvasive monitoring of cerebral oxygenation in traumatic brain injury: a mix of doubts and hope.

Authors:  Andrew I R Maas; Giuseppe Citerio
Journal:  Intensive Care Med       Date:  2010-05-26       Impact factor: 17.440

2.  Cerebral near infrared spectroscopy is a reliable marker of systemic perfusion in awake single ventricle children.

Authors:  Paul M Kirshbom; Joseph M Forbess; Brian E Kogon; Janet M Simsic; Dennis W Kim; Anthony A Raviele; Kirk R Kanter; Robert N Vincent
Journal:  Pediatr Cardiol       Date:  2007-01-02       Impact factor: 1.655

Review 3.  In vivo validation of cerebral near-infrared spectroscopy: a review.

Authors:  Amalie la Cour; Gorm Greisen; Simon Hyttel-Sorensen
Journal:  Neurophotonics       Date:  2018-11-27       Impact factor: 3.593

4.  Perioperative care of the infant with single ventricle physiology.

Authors:  Vamsi V Yarlagadda; Melvin C Almodovar
Journal:  Curr Treat Options Cardiovasc Med       Date:  2011-10

Review 5.  Anesthesia and postoperative analgesia in pediatric patients undergoing cardiac surgery.

Authors:  Laura K Diaz
Journal:  Paediatr Drugs       Date:  2006       Impact factor: 3.022

Review 6.  [Anesthetic management of surgery in term and preterm infants].

Authors:  C Breschan; R Likar
Journal:  Anaesthesist       Date:  2006-10       Impact factor: 1.041

7.  Noninvasive cerebral oximeter as a surrogate for mixed venous saturation in children.

Authors:  Adnan T Bhutta; Jesse W Ford; James G Parker; Parthak Prodhan; Eudice E Fontenot; Paul M Seib; Brittany I Stroope; Elizabeth A Frazier; Michael L Schmitz; Jonathan J Drummond-Webb; William R Morrow
Journal:  Pediatr Cardiol       Date:  2007-01-09       Impact factor: 1.655

Review 8.  Cerebral and tissue oximetry.

Authors:  Jochen Steppan; Charles W Hogue
Journal:  Best Pract Res Clin Anaesthesiol       Date:  2014-09-28

9.  Central venous oxygen saturation and blood lactate levels during cardiopulmonary bypass are associated with outcome after pediatric cardiac surgery.

Authors:  Marco Ranucci; Giuseppe Isgrò; Concetta Carlucci; Teresa De La Torre; Stefania Enginoli; Alessandro Frigiola
Journal:  Crit Care       Date:  2010-08-04       Impact factor: 9.097

10.  Neurocognitive monitoring and care during pediatric cardiopulmonary bypass-current and future directions.

Authors:  Jennifer K Lee; R Blaine Easley; Kenneth M Brady
Journal:  Curr Cardiol Rev       Date:  2008-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.