Literature DB >> 15910077

Refractive correction method for digital charge-coupled device-recorded Scheimpflug photographs by means of ray tracing.

Wolfgang Fink1.   

Abstract

Our purpose is to correct digital CCD-recorded Scheimpflug photographs, imaging both the anterior and posterior corneal surface, the anterior chamber, and the anterior eye lens surface for optical distortions. In a ray-tracing algorithm the imaging of the posterior corneal surface in a given Scheimpflug photograph is corrected by applying Snell's law on parallel incident rays entering through the anterior corneal surface. Once the posterior corneal surface is corrected, the procedure is repeated, again with parallel incident rays entering through both the anterior and now corrected posterior corneal surface, to correct the imaging of the anterior eye lens surface. The refractive indices necessary for Snell's law are taken from Gullstrand's exact schematic eye model. Due to the optical/refractive correction, the digital Scheimpflug photograph decreases in size perpendicular to the direction of the optical axis. As a consequence the curvature radii of both the posterior corneal surface and the anterior lens surface are reduced significantly, as compared to the original digital Scheimpflug photograph. Furthermore, the corneal thickness and the anterior chamber depth are increased. The presented refractive correction method enables us to extract from Scheimpflug photographs the following quantities rather realistically: structure coordinates and curvature radii of both the posterior corneal surface and the anterior lens surface, corneal thickness, and anterior chamber depth. This method can readily be applied to other imaged quantities, such as the posterior eye lens surface, the lens thickness, and the pupillary opening. Copyright 2005 Society of Photo-Optical Instrumentation Engineers.

Entities:  

Mesh:

Year:  2005        PMID: 15910077     DOI: 10.1117/1.1899683

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  3 in total

1.  Extralenticular and lenticular aspects of accommodation and presbyopia in human versus monkey eyes.

Authors:  Mary Ann Croft; Jared P McDonald; Alexander Katz; Ting-Li Lin; Elke Lütjen-Drecoll; Paul L Kaufman
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-07-26       Impact factor: 4.799

Review 2.  Femtosecond laser assisted cataract surgery, beginning of a new era in cataract surgery.

Authors:  Muhammad Hassaan Ali; Mamoona Javaid; Samreen Jamal; Nadeem Hafeez Butt
Journal:  Oman J Ophthalmol       Date:  2015 Sep-Dec

3.  Changes in Central Corneal Thickness With Air-Puff-Induced Corneal Deformation Using a Method to Correct Scheimpflug and Refractive Distortion.

Authors:  Monica D Okon; Yanhui Ma; Jun Liu; Cynthia J Roberts
Journal:  J Refract Surg       Date:  2021-06-01       Impact factor: 3.255

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.