Literature DB >> 15906795

Measurements of urinary bladder volume: comparison of five ultrasound calculation methods in volunteers.

Mauro Dicuio1, Giorgio Pomara, Filippo Menchini Fabris, Valeria Ales, Christer Dahlstrand, Girolamo Morelli.   

Abstract

OBJECTIVES: To assess the precision of five different calculation methods in real-time bladder volume measurement.
MATERIAL AND METHODS: Bladders from 10 medical staff volunteers were examined. Two examinations of each subject were performed by one examiner using the same ultrasound scannet Five different calculation algorithms were used on the frozen ultrasound pictures: the prolate ellipsoid method based on the formula: volume = length x width x heigth x 0.52 on two dimensions; the double area method based on the formula: volume = ex [C1 + C2 x ln(A1) + C3 x ln(A2)] on two dimensions; The double ellipsoid method on two dimensions; the method of one dimension of the shape of the bladder outlined manually with the maximal longitudinal diameter; the method of one dimension of the shape of the bladder outlined by smooth ellipsoid with the maximal longitudinal diameter After registration of the voided volume the subjects were scanned again in order to assure complete emptying.
RESULTS: Voided volumes ranged from 120 ml to 465 ml. The precision of each method was equal. Errors were not more than 25% of the voided volume. No significant improvement in accuracy for any of the methods was found.
CONCLUSIONS: Ultrasound bladder volume calculation is an easy method for estimation of bladder volume. Errors can be reasonably accepted. Large variation, irrespective of methods, from the true bladder volume, indicates that the clinical evaluation of ultrasound bladder measurement must be interpreted with great care in some patients.

Entities:  

Mesh:

Year:  2005        PMID: 15906795

Source DB:  PubMed          Journal:  Arch Ital Urol Androl        ISSN: 1124-3562


  15 in total

Review 1.  Ambulatory urodynamic monitoring: state of the art and future directions.

Authors:  Benjamin Abelson; Steve Majerus; Daniel Sun; Bradley C Gill; Eboo Versi; Margot S Damaser
Journal:  Nat Rev Urol       Date:  2019-05       Impact factor: 14.432

2.  Reducing postoperative catheterisation after anterior colporrhaphy from 48 to 24 h: a randomised controlled trial.

Authors:  Sergi Fernandez-Gonzalez; Eva Martinez Franco; Rubén Martínez-Cumplido; Cristina Molinet Coll; Funesanta Ojeda González; Maria Dolores Gómez Roig; Lluís Amat Tardiu
Journal:  Int Urogynecol J       Date:  2018-11-27       Impact factor: 2.894

3.  My patient has abdominal and flank pain: Identifying renal causes.

Authors:  Christopher Cox; Scott MacDonald; Ryan Henneberry; Paul R Atkinson
Journal:  Ultrasound       Date:  2015-08-17

4.  Contasure-needleless® compared with Monarc® for the treatment of stress urinary incontinence.

Authors:  Sergi Fernandez-Gonzalez; Eva Martinez Franco; Xinxin Lin Miao; Lluis Amat Tardiu
Journal:  Int Urogynecol J       Date:  2016-12-26       Impact factor: 2.894

5.  Characteristics of the bladder in infants with urinary tract infections: an ultrasound study.

Authors:  Ji-Xian Liu; Vivian Yee-Fong Leung; Winnie Chiu-Wing Chu; Biji Sreedhar; Constantine Metreweli; Chung-Kwong Yeung
Journal:  Pediatr Radiol       Date:  2008-08-08

6.  Acceptable Postvoid Residual Urine Volume after Vaginal Delivery and Its Association with Various Obstetric Parameters.

Authors:  Wen Sze Choe; Beng Kwang Ng; Ixora Kamisan Atan; Pei Shan Lim
Journal:  Obstet Gynecol Int       Date:  2018-08-06

7.  Development and evaluation of automated ultrasonographic detection of bladder diameter for estimation of bladder urine volume.

Authors:  Masaru Matsumoto; Takuya Tsutaoka; Koichi Yabunaka; Mayumi Handa; Mikako Yoshida; Gojiro Nakagami; Hiromi Sanada
Journal:  PLoS One       Date:  2019-09-05       Impact factor: 3.240

8.  Point-of-care ultrasound findings in unselected patients in an emergency department -results from a prospective observational trial.

Authors:  Jesper Weile; Christian B Laursen; Christian A Frederiksen; Ole Graumann; Erik Sloth; Hans Kirkegaard
Journal:  BMC Emerg Med       Date:  2018-12-27

9.  Comprehensive MR Urography Protocol: Equally Good Diagnostic Performance and Enhanced Visibility of the Upper Urinary Tract Compared to Triple-Phase CT Urography.

Authors:  Mazen Sudah; Amro Masarwah; Sakari Kainulainen; Marja Pitkänen; Hanna Matikka; Vaiva Dabravolskaite; Sirpa Aaltomaa; Ritva Vanninen
Journal:  PLoS One       Date:  2016-07-06       Impact factor: 3.240

10.  Effectiveness of intramuscular neostigmine to accelerate bladder emptying after spinal anesthesia.

Authors:  Tjokorda Gde Agung Senapathi; Made Wiryana; I Made Subagiartha; I Putu Pramana Suarjaya; I Made Gede Widnyana; Ida Bagus Krisna Jaya Sutawan; A A Gde Putra Semara Jaya; Andri Thewidya
Journal:  Ther Clin Risk Manag       Date:  2018-09-11       Impact factor: 2.423

View more