The effect of B1 field inhomogeneity and the nonselective inversion profile on the kinetics of FAIR-based perfusion MRI.

Janneke Schepers1, Matthias J P van Osch, Lambertus W Bartels, Sean N Heukels, Max A Viergever, Klaas Nicolay.   

Abstract

Perfusion imaging with pulsed arterial spin labeling techniques, like flow-sensitive alternating inversion recovery (FAIR), may suffer from inflow of fresh, i.e., unlabeled, spins. Inflow of fresh spins is caused by the arrival of unlabeled spins in the image slice and can lead to underestimation of the perfusion if not taken into account. In this study it was shown that a decrease in B(1) field strength toward the edge of the transmit coil and the consequent reduction in the inversion efficiency leads to a narrowing of the arterial delivery function and a reduction in FAIR signal. Increasing the B(1) amplitude of the adiabatic inversion pulse from 2.3 to 5.7 times its minimum amplitude requirement resulted in an observed increase of 40 to 80% in the rat brain FAIR signal at inflow times longer than 0.65 s. For coils with limited dimensions and significant B(1) inhomogeneity over the perfusion labeling slab, the application of an excessively large B(1) amplitude in combination with adiabatic inversion is recommended to optimize the FAIR perfusion contrast.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15906290     DOI: 10.1002/mrm.20480

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  3 in total

1.  Heterogeneous increases of regional cerebral blood flow during preterm brain development: Preliminary assessment with pseudo-continuous arterial spin labeled perfusion MRI.

Authors:  Minhui Ouyang; Peiying Liu; Tina Jeon; Lina Chalak; Roy Heyne; Nancy K Rollins; Daniel J Licht; John A Detre; Timothy P L Roberts; Hanzhang Lu; Hao Huang
Journal:  Neuroimage       Date:  2016-12-14       Impact factor: 6.556

2.  Optimization and validation of methods for mapping of the radiofrequency transmit field at 3T.

Authors:  Antoine Lutti; Chloe Hutton; Jürgen Finsterbusch; Gunther Helms; Nikolaus Weiskopf
Journal:  Magn Reson Med       Date:  2010-07       Impact factor: 4.668

3.  Investigating white matter perfusion using optimal sampling strategy arterial spin labeling at 7 Tesla.

Authors:  Alexander G Gardener; Peter Jezzard
Journal:  Magn Reson Med       Date:  2014-06-20       Impact factor: 4.668

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.