Literature DB >> 15903169

Functional restoration of implants on the day of surgical placement in the fully edentulous mandible: a case series.

Alexandre-Amir Aalam1, Hessam Nowzari, Alina Krivitsky.   

Abstract

PURPOSE: The purpose of this article is to report the clinical experience and outcome of a study of the functional rehabilitation of 16 completely edentulous mandibles with immediately loaded cross-arch screw-retained hybrid prostheses at the University of Southern California.
MATERIALS AND METHODS: After signing informed consent forms 16 patients (9 male, 7 female) aged 47 to 84 years (mean age, 62.6+/-11.6 years) received 90 Brånemark System Mk III dental implants (Nobel Biocare USA, Yorba Linda, CA, USA). Stability and radiographs of the dental implants were evaluated at the time of surgery, at 3 months, at 1 year, and at 3 years post loading.
RESULTS: Three implants failed to meet the criteria of success, bringing the cumulative success rate to 96.6%, with a 100% prosthetic success rate at 3 years. Thirty-nine (43.3%) of the dental implants placed were 15 mm in length. Seventy-seven (85.5%) of the dental implants were placed in high-density bone. At 3 years post loading, the average bone loss was -1.2+/-0.1 mm.
CONCLUSION: Within the limitations of this study, restoration of implants by unreinforced hybrid prostheses at the time of placement provided satisfactory results. The outcome was stable at 3 years post restoration. Mandibular rehabilitation by functional loading of the implants on the day of the insertion requires the comprehension and proper application of surgical and restorative principles.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15903169     DOI: 10.1111/j.1708-8208.2005.tb00041.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  4 in total

Review 1.  Diagnostic imaging of trabecular bone microstructure for oral implants: a literature review.

Authors:  N Ibrahim; A Parsa; B Hassan; P van der Stelt; D Wismeijer
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

2.  Redesign of a fixture mount to be used as an impression coping and a provisional abutment as well.

Authors:  Glenn Hsuan-Chen Chang; Chen Tian; Yuen-Siang Hung
Journal:  Contemp Clin Dent       Date:  2011-07

3.  Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study.

Authors:  Du-Hyeong Lee; Seo-Young An; Min-Ho Hong; Kyoung-Bae Jeon; Kyu-Bok Lee
Journal:  J Adv Prosthodont       Date:  2016-06-17       Impact factor: 1.904

4.  Immediate function on the day of surgery compared with a delayed implant loading process in the mandible: a randomized clinical trial over 5 years.

Authors:  Asbjorn Jokstad; Hassan Alkumru
Journal:  Clin Oral Implants Res       Date:  2013-10-23       Impact factor: 5.977

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.