Literature DB >> 15900241

Postoperative bronchial stump fistula responding well to occlusion with metallic coils and fibrin glue via a tracheostomy: a case report.

Junzo Shimizu1, Masaya Takizawa, Tsuyoshi Yachi, Yoshihiko Arano, Yasumitsu Hirano, Ryuichi Waseda, Shiro Takahashi, Yoshio Tsunezuka.   

Abstract

An 80-year-old man underwent middle and lower lobectomy of the right lung to treat squamous cell carcinoma (SCC) (4 cm in diameter) originating from the right B4 bronchus. On the 4th postoperative day, a massive air leak from the thoracic drain was noted. At that time, a diagnosis of bronchial stump fistula was made on the basis of the bronchoscopic findings. Continuous thoracic drainage, aspiration of sputum via a tracheostomy and intravenous administration of antibiotics were performed immediately after the diagnosis. However, the patient's condition was complicated by aspiration pneumonia. On the 11th postoperative day, bronchoscopic procedure to close the bronchial fistula was performed via the tracheostomy. During this procedure, metallic coils were first inserted into the fistula to serve as the core for occlusion. Then, instead of directly infusing fibrin glue, several small beans-sized pieces of Surgicell cotton (Johnson & Johnson Co., Cincinnati, OH) soaked in fluid A (concentrated fibrinogen) and the same number of Surgicell cotton pieces soaked in fluid B (thrombin) were alternately inserted into the fistula, to allow closure of the bronchial fistula. After this procedure, the embolus created remained in place without being expectorated, and the aspiration pneumonia entered remission, allowing the patient to be discharged from the hospital on the 24th postoperative day. At preset, 14 months after surgery, the patient is in good condition. This technique allows simple and reliable closure of a fistula if a tracheostomy is available. It should be selected as a therapy of first choice when dealing with patients with a postoperative bronchial stump fistula in poor general condition. Patients undergoing right pneumonectomy or middle and lower lobectomy of the right lung should be considered as belonging to a high risk group for bronchial fistula and as requiring preventable measures (e.g., covering the stump with an intercostal muscle flap).

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15900241

Source DB:  PubMed          Journal:  Ann Thorac Cardiovasc Surg        ISSN: 1341-1098            Impact factor:   1.520


  3 in total

1.  Intrabronchial Valves for Air Leaks After Lobectomy, Segmentectomy, and Lung Volume Reduction Surgery.

Authors:  Muhanned Abu-Hijleh; Kim Styrvoky; Vikram Anand; Fernando Woll; Lonny Yarmus; Michael S Machuzak; Daniel A Nader; Timothy W Mullett; D Kyle Hogarth; Jennifer W Toth; Ghazwan Acash; Roberto F Casal; Stephen Hazelrigg; Douglas E Wood
Journal:  Lung       Date:  2019-08-28       Impact factor: 2.584

Review 2.  Bronchoscopic management of prolonged air leak.

Authors:  Sevak Keshishyan; Alberto E Revelo; Oleg Epelbaum
Journal:  J Thorac Dis       Date:  2017-09       Impact factor: 2.895

3.  Postoperative bronchial stump fistula after lobectomy: response to occlusion with polyglycolic acid mesh and fibrin glue via bronchoscopy.

Authors:  Kazuhiro Imai; Ikuo Matsuzaki; Yoshihiro Minamiya; Hajime Saito; Satoru Yoshida; Kyo Hirayama; Takeyuki Sawano; Jun-ichi Ogawa
Journal:  Gen Thorac Cardiovasc Surg       Date:  2011-11-15