Literature DB >> 15900056

Real-time blood-pool images of contrast enhanced ultrasound with Definity in the detection of tumour nodules in the liver.

H Maruyama1, S Matsutani, H Saisho, Y Mine, N Kamiyama, T Hirata, M Sasamata.   

Abstract

Lower mechanical index (MI) technique with newer microbubble agents has been introduced into clinical practice as a newer ultrasound (US) imaging. However, the efficacy in detecting tumour nodules has not been proven scientifically. The aim of this study was to elucidate the efficacy of a blood-pool image of real-time contrast-enhanced US under low MI in detecting liver tumours. 15 rabbits with VX-2 tumour were used; the number of implantations was none in two rabbits, one in four, two in five and three in four. US equipment was APLIO (Toshiba) with linear probe (3.5/7.0 MHz). The number, location and size of tumour nodules were examined by non-contrast tissue harmonic imaging (NC-US) or contrast-enhanced pulse subtraction harmonic imaging (C-US) under extra-low MI (MI 0.065) with the injection of Definity (30 microl kg(-1)). The number of tumour nodules detected by both NC-US and C-US were consistent with the histopathological results in five rabbits - two with none, two with one nodule and one with two nodules. In the other 10 rabbits, C-US showed all the implanted tumours and small daughter nodules around them that were confirmed by histopathology. However, NC-US failed to demonstrate two implanted nodules and all the daughter nodules. On the basis of the histopathological results, detectability of implanted tumour was not significantly different between NC-US (24/26, 92.3%) and C-US (26/26, 100%). However C-US was superior to NC-US in delineating the nodules and in detecting small daughter nodules. The sizes of the implanted tumour nodules measured by histopathology correlated closely with those measured by C-US. Real-time blood-pool images by pulse subtraction harmonic imaging under extra-low MI with Definity will contribute to the improvement of the ultrasound delineation and detection of liver tumours.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15900056     DOI: 10.1259/bjr/59648297

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  3 in total

Review 1.  Recent applications of ultrasound: diagnosis and treatment of hepatocellular carcinoma.

Authors:  Hitoshi Maruyama; Masaaki Ebara
Journal:  Int J Clin Oncol       Date:  2006-08       Impact factor: 3.402

2.  Assessment of hepatic VX(2) tumors with combined percutaneous transhepatic lymphosonography and contrast-enhanced ultrasonographic imaging.

Authors:  Cun Liu; Ping Liang; Yang Wang; Pei Zhou; Xin Li; Zhi-Yu Han; Shao-Ping Liu
Journal:  World J Gastroenterol       Date:  2008-06-28       Impact factor: 5.742

Review 3.  Evolution of contrast agents for ultrasound imaging and ultrasound-mediated drug delivery.

Authors:  Vera Paefgen; Dennis Doleschel; Fabian Kiessling
Journal:  Front Pharmacol       Date:  2015-09-15       Impact factor: 5.810

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.