Literature DB >> 15898381

Sandblasted metal brackets bonded with resin-modified glass ionomer cement in vivo.

Mete Ozer1, Selim Arici.   

Abstract

The aim of this in vivo study was to evaluate the effects of sandblasting metal brackets on their clinical performance when resin-modified, chemically cured glass ionomer cement was used for bonding. A total of 60 patients with a range of malocclusions were allocated randomly into two groups. For the first 30 cases, teeth were divided into quadrants so that sandblasted, mesh-based metal brackets (SB) were bonded directly to the upper left and lower right quadrants using the resin-modified glass ionomer cement. The mesh-based (no sandblasting) brackets bonded to the other quadrants with the same adhesive were used as control (CO). A split-mouth design was used, and the allocation of the brackets per quadrant was reversed for the second 30 cases. Sandblasting of the bracket bases was accomplished using 25-microm aluminum oxide particles for three seconds. The manufacturer's instructions were followed for bonding. The number, site, and date of first-time bracket failures were monitored throughout active orthodontic treatment, and the observation time was 20 months. The bond failure rates were 4.9% and 4.3% for the SB and CO brackets, respectively. No statistically significant difference was found between the groups for failure rates. The bond failure sites were predominantly at the enamel-adhesive interface in both groups. Sandblasting did not have a positive effect on the clinical performance of the mesh-based metal brackets when bonded with resin-modified glass ionomer cement.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15898381     DOI: 10.1043/0003-3219(2005)75[406:SMBBWR]2.0.CO;2

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  3 in total

Review 1.  Retention of orthodontic brackets bonded with resin-modified GIC versus composite resin adhesives--a quantitative systematic review of clinical trials.

Authors:  Steffen Mickenautsch; Veerasamy Yengopal; Avijit Banerjee
Journal:  Clin Oral Investig       Date:  2011-10-18       Impact factor: 3.573

2.  A comparative evaluation of the retention of metallic brackets bonded with resin-modified glass ionomer cement under different enamel preparations: A pilot study.

Authors:  Padmaja Sharma; Ashima Valiathan; Ankit Arora; Sachin Agarwal
Journal:  Contemp Clin Dent       Date:  2013-04

3.  Shear bond strength of new and rebonded orthodontic brackets to the enamel surfaces.

Authors:  Fouad Salama; Hessa Alrejaye; Malak Aldosari; Naif Almosa
Journal:  J Orthod Sci       Date:  2018-06-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.