Literature DB >> 15895603

Physical characteristics of a low-dose gas microstrip detector for orthopedic x-ray imaging.

Philippe Després1, Gilles Beaudoin, Pierre Gravel, Jacques A de Guise.   

Abstract

A new scanning slit gas detector dedicated to orthopedic x-ray imaging is presented and evaluated in terms of its fundamental imaging characteristics. The system is based on the micromesh gaseous structure detector and achieves primary signal amplification through electronic avalanche in the gas. This feature, together with high quantum detection efficiency and fan-beam geometry, allows for imaging at low radiation levels. The system is composed of 1764 channels spanning a width of 44.8 cm and is capable of imaging an entire patient at speeds of up to 15 cm/s. The resolution was found to be anisotropic and significantly affected by the beam quality in the horizontal direction, but otherwise sufficient for orthopedic studies. As a consequence of line-by-line acquisition, the images contain some ripple components due to mechanical vibrations combined with variations in the x-ray tube output power. The reported detective quantum efficiency (DQE) values are relatively low (0.14 to 0.20 at 0.5 mm(-1)) as a consequence of a suboptimal collimation geometry. The DQE values were found to be unaffected by the exposure down to 7 microGy, suggesting that the system is quantum limited even for low radiation levels. A system composed of two orthogonal detectors is already in use and can produce dual-view full body scans at low doses. This device could contribute to reduce the risk of radiation induced cancer in sensitive clientele undergoing intensive x-ray procedures, like young scoliotic women.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15895603     DOI: 10.1118/1.1876592

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Measuring physiological and pathological femoral anteversion using a biplanar low-dose X-ray system: validity, reliability, and discriminative ability in cerebral palsy.

Authors:  Matthias Thépaut; Sylvain Brochard; Julien Leboucher; Mathieu Lempereur; Eric Stindel; Valentin Tissot; Bhushan S Borotikar
Journal:  Skeletal Radiol       Date:  2015-11-27       Impact factor: 2.199

2.  Adolescent idiopathic scoliosis treated with posteromedial translation: radiologic evaluation with a 3D low-dose system.

Authors:  Brice Ilharreborde; Guy Sebag; Wafa Skalli; Keyvan Mazda
Journal:  Eur Spine J       Date:  2013-04-12       Impact factor: 3.134

3.  Comparison of radiation dose, workflow, patient comfort and financial break-even of standard digital radiography and a novel biplanar low-dose X-ray system for upright full-length lower limb and whole spine radiography.

Authors:  Tobias J Dietrich; Christian W A Pfirrmann; Alexander Schwab; Katja Pankalla; Florian M Buck
Journal:  Skeletal Radiol       Date:  2013-03-28       Impact factor: 2.199

4.  Sagittal alignment of the cervical spine in adolescent idiopathic scoliosis treated by posteromedial translation.

Authors:  Brice Ilharreborde; Christophe Vidal; Wafa Skalli; Keyvan Mazda
Journal:  Eur Spine J       Date:  2012-09-11       Impact factor: 3.134

  4 in total