Literature DB >> 15895582

Three-dimensional fluorescence lifetime tomography.

Anuradha Godavarty1, Eva M Sevick-Muraca, Margaret J Eppstein.   

Abstract

Near-infrared fluorescence tomography using molecularly targeted lifetime-sensitive, fluorescent contrast agents have applications for early-stage cancer diagnostics. Yet, although the measurement of fluorescent lifetime imaging microscopy (FLIM) is extensively used in microscopy and spectroscopy applications, demonstration of fluorescence lifetime tomography for medical imaging is limited to two-dimensional studies. Herein, the feasibility of three-dimensional fluorescence-lifetime tomography on clinically relevant phantom volumes is established, using (i) a gainmodulated intensified charge coupled device (CCD) and modulated laser diode imaging system, (ii) two fluorescent contrast agents, e.g., Indocyanine green and 3-3'-Diethylthiatricarbocyanine iodide differing in their fluorescence lifetime by 0.62 ns, and (iii) a two stage approximate extended Kalman filter reconstruction algorithm. Fluorescence measurements of phase and amplitude were acquired on the phantom surface under different target to background fluorescence absorption (70:1, 100:1) and fluorescence lifetime (1:1, 2.1:1) contrasts at target depths of 1.4-2 cm. The Bayesian tomography algorithm was employed to obtain three-dimensional images of lifetime and absorption owing to the fluorophores.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15895582     DOI: 10.1118/1.1861160

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  30 in total

Review 1.  In vivo optical imaging and dynamic contrast methods for biomedical research.

Authors:  Elizabeth M C Hillman; Cyrus B Amoozegar; Tracy Wang; Addason F H McCaslin; Matthew B Bouchard; James Mansfield; Richard M Levenson
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2011-11-28       Impact factor: 4.226

Review 2.  Fluorescence lifetime measurements and biological imaging.

Authors:  Mikhail Y Berezin; Samuel Achilefu
Journal:  Chem Rev       Date:  2010-05-12       Impact factor: 60.622

3.  Fully linear reconstruction method for fluorescence yield and lifetime through inverse complex-source formulation: simulation studies.

Authors:  Hao Gao; Yuting Lin; Gultekin Gulsen; Hongkai Zhao
Journal:  Opt Lett       Date:  2010-06-01       Impact factor: 3.776

Review 4.  Using in-vivo fluorescence imaging in personalized cancer diagnostics and therapy, an image and treat paradigm.

Authors:  Y Ardeshirpour; V Chernomordik; J Capala; M Hassan; R Zielinsky; G Griffiths; S Achilefu; P Smith; A Gandjbakhche
Journal:  Technol Cancer Res Treat       Date:  2011-12

5.  Molecular fluorescence, phosphorescence, and chemiluminescence spectrometry.

Authors:  Kristin A Fletcher; Sayo O Fakayode; Mark Lowry; Sheryl A Tucker; Sharon L Neal; Irene W Kimaru; Matthew E McCarroll; Gabor Patonay; Philip B Oldham; Oleksandr Rusin; Robert M Strongin; Isiah M Warner
Journal:  Anal Chem       Date:  2006-06-15       Impact factor: 6.986

Review 6.  Lymphatic imaging in humans with near-infrared fluorescence.

Authors:  John C Rasmussen; I-Chih Tan; Milton V Marshall; Caroline E Fife; Eva M Sevick-Muraca
Journal:  Curr Opin Biotechnol       Date:  2009-02-23       Impact factor: 9.740

7.  Fluorescence lifetime imaging system for in vivo studies.

Authors:  Moinuddin Hassan; Jason Riley; Victor Chernomordik; Paul Smith; Randall Pursley; Sang Bong Lee; Jacek Capala; Amir H Gandjbakhche
Journal:  Mol Imaging       Date:  2007 Jul-Aug       Impact factor: 4.488

8.  A comparison between time domain and spectral imaging systems for imaging quantum dots in small living animals.

Authors:  Adam de la Zerda; Sunil Bodapati; Robert Teed; Meike L Schipper; Shay Keren; Bryan R Smith; Johnny S T Ng; Sanjiv Sam Gambhir
Journal:  Mol Imaging Biol       Date:  2009-12-10       Impact factor: 3.488

9.  Tracking dynamics of muscle engraftment in small animals by in vivo fluorescent imaging.

Authors:  Zhong Yang; Qing Zeng; Zhiyuan Ma; Yaming Wang; Xiaoyin Xu
Journal:  J Vis Exp       Date:  2009-09-21       Impact factor: 1.355

10.  Combined fluorescence and X-Ray tomography for quantitative in vivo detection of fluorophore.

Authors:  W C Barber; Y Lin; O Nalcioglu; J S Iwanczyk; N E Hartsough; G Gulsen
Journal:  Technol Cancer Res Treat       Date:  2010-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.