Literature DB >> 15895569

Effects of x-ray and CT image enhancements on the robustness and accuracy of a rigid 3D/2D image registration.

Jinkoo Kim1, Fang-Fang Yin, Yang Zhao, Jae Ho Kim.   

Abstract

A rigid body three-dimensional/two-dimensional (3D/2D) registration method has been implemented using mutual information, gradient ascent, and 3D texturemap-based digitally reconstructed radiographs. Nine combinations of commonly used x-ray and computed tomography (CT) image enhancement methods, including window leveling, histogram equalization, and adaptive histogram equalization, were examined to assess their effects on accuracy and robustness of the registration method. From a set of experiments using an anthropomorphic chest phantom, we were able to draw several conclusions. First, the CT and x-ray preprocessing combination with the widest attraction range was the one that linearly stretched the histograms onto the entire display range on both CT and x-ray images. The average attraction ranges of this combination were 71.3 mm and 61.3 deg in the translation and rotation dimensions, respectively, and the average errors were 0.12 deg and 0.47 mm. Second, the combination of the CT image with tissue and bone information and the x-ray images with adaptive histogram equalization also showed subvoxel accuracy, especially the best in the translation dimensions. However, its attraction ranges were the smallest among the examined combinations (on average 36 mm and 19 deg). Last the bone-only information on the CT image did not show convergency property to the correct registration.

Mesh:

Year:  2005        PMID: 15895569     DOI: 10.1118/1.1869592

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  A method of image registration for small animal, multi-modality imaging.

Authors:  Patrick L Chow; David B Stout; Evangelia Komisopoulou; Arion F Chatziioannou
Journal:  Phys Med Biol       Date:  2006-01-04       Impact factor: 3.609

2.  Automatic registration of CT volumes and dual-energy digital radiography for detection of cardiac and lung diseases.

Authors:  Baowei Fei; Xiang Chen; Hesheng Wang; John M Sabol; Elena DuPont; Robert C Gilkeson
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

3.  A frequency-based approach to locate common structure for 2D-3D intensity-based registration of setup images in prostate radiotherapy.

Authors:  Reshma Munbodh; Zhe Chen; David A Jaffray; Douglas J Moseley; Jonathan P S Knisely; James S Duncan
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

4.  Validation for 2D/3D registration. II: The comparison of intensity- and gradient-based merit functions using a new gold standard data set.

Authors:  Christelle Gendrin; Primoz Markelj; Supriyanto Ardjo Pawiro; Jakob Spoerk; Christoph Bloch; Christoph Weber; Michael Figl; Helmar Bergmann; Wolfgang Birkfellner; Bostjan Likar; Franjo Pernus
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

5.  Evaluation of Image Enhancement Method on Target Registration Using Cone Beam CT in Radiation Therapy.

Authors:  Hui Yan; Ren Lei; Jackie Wu; Fu Di; Fang-Fang Yin
Journal:  Clin Med Oncol       Date:  2008-03-28

6.  3D-2D Deformable Image Registration Using Feature-Based Nonuniform Meshes.

Authors:  Zichun Zhong; Xiaohu Guo; Yiqi Cai; Yin Yang; Jing Wang; Xun Jia; Weihua Mao
Journal:  Biomed Res Int       Date:  2016-02-25       Impact factor: 3.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.