Literature DB >> 15894880

Reverse-geometry gas-permeable lens design for pellucid marginal degeneration.

Jill Liu1, Norman E Leach, Jan P G Bergmanson.   

Abstract

PURPOSE: To report a case of treating a patient with pellucid marginal degeneration (PMD) by using a reverse-geometry gas-permeable lens design.
METHODS: A 38-year-old Hispanic man was referred for having reduced visual acuity secondary to distorted corneas. The patient was diagnosed with PMD after an extensive slitlamp examination showed a thinning of the inferior peripheral cornea in both eyes. Corneal topography (Orbscan II) was performed to help confirm the diagnosis. A Reverse Aspheric Ortho Focus (RAOF) gas-permeable lens was fitted on this patient.
RESULTS: The Orbscan II corneal topography showed distinct peripheral steepening, a pronounced astigmatic pattern (greater in the left eye than in the right), and thinner corneas in the inferior periphery than centrally. The fluorescein pattern of the RAOF 5 lenses showed central alignment, good edge lift 360 degrees, mid peripheral bearing with 0.5 mm vertical movement on blinking, and good centration. The patient's distance visual acuity with the lenses was 20/20-1 in the right eye and 20/20 in the left.
CONCLUSIONS: The Orbscan II was an important tool in making the diagnosis of early PMD, because few clinical signs were observed. Not only does the Orbscan II provide the clinician with a topographic map of the cornea, but it also measures the corneal thickness, which aided in the diagnosis of this patient. In addition, the posterior float measurement provided by the Orbscan II may be instrumental in making a differential diagnosis. A reverse-geometry gas-permeable lens provided the patient with improved peripheral fit over conventional designs, adequate comfort, and optimal visual acuity.

Entities:  

Mesh:

Year:  2005        PMID: 15894880     DOI: 10.1097/01.icl.0000142380.78861.89

Source DB:  PubMed          Journal:  Eye Contact Lens        ISSN: 1542-2321            Impact factor:   2.018


  4 in total

1.  Pellucid marginal corneal degeneration: evaluation of the corneal surface and contact lens fitting.

Authors:  C Gruenauer-Kloevekorn; U Fischer; K Kloevekorn-Norgall; G I W Duncker
Journal:  Br J Ophthalmol       Date:  2006-03       Impact factor: 4.638

2.  Full-Ring Intracorneal Implantation in Corneas With Pellucid Marginal Degeneration.

Authors:  Sahar Mojaled Nobari; Consuelo Villena; Khosrow Jadidi
Journal:  Iran Red Crescent Med J       Date:  2015-12-26       Impact factor: 0.611

3.  Comparison of central corneal thickness measurements using ultrasound pachymetry, ultrasound biomicroscopy, and the Artemis-2 VHF scanner in normal eyes.

Authors:  Haya M Al-Farhan; Wafa'a Majed Al-Otaibi
Journal:  Clin Ophthalmol       Date:  2012-07-06

4.  Fitting Tips and Visual Rehabilitation of Irregular Cornea with a New Design of Corneoscleral Contact Lens: Objective and Subjective Evaluation.

Authors:  Waleed Ali Abou Samra; Amani E Badawi; Hanem Kishk; Ayman Abd El Ghafar; Mohamed M Elwan; Hossam Youssef Abouelkheir
Journal:  J Ophthalmol       Date:  2018-02-01       Impact factor: 1.909

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.