Literature DB >> 15894878

Ocular surface temperature: a review.

Christine Purslow1, James S Wolffsohn.   

Abstract

PURPOSE: To review the evolution in ocular temperature measurement during the last century and examine the advantages and applications of the latest noncontact techniques. The characteristics and source of ocular surface temperature are also discussed.
METHODS: The literature was reviewed with regard to progress in human thermometry techniques, the parallel development in ocular temperature measurement, the current use of infrared imaging, and the applications of ocular thermography.
RESULTS: It is widely acknowledged that the ability to measure ocular temperature accurately will increase the understanding of ocular physiology. There is a characteristic thermal profile across the anterior eye, in which the central area appears coolest. Ocular surface temperature is affected by many factors, including inflammation. In thermometry of the human eye, contact techniques have largely been superseded by infrared imaging, providing a noninvasive and potentially more accurate method of temperature measurement. Ocular thermography requires high resolution and frame rate: features found in the latest generation of cameras. Applications have included dry eye, contact lens wear, corneal sensitivity, and refractive surgery.
CONCLUSIONS: Interest in the temperature of the eye spans almost 130 years. It has been an area of research largely driven by prevailing technology. Current instrumentation offers the potential to measure ocular surface temperature with more accuracy, resolution, and speed than previously possible. The use of dynamic ocular thermography offers great opportunities for monitoring the temperature of the anterior eye.

Entities:  

Mesh:

Year:  2005        PMID: 15894878     DOI: 10.1097/01.icl.0000141921.80061.17

Source DB:  PubMed          Journal:  Eye Contact Lens        ISSN: 1542-2321            Impact factor:   2.018


  36 in total

1.  Evidence for the major contribution of evaporation to tear film thinning between blinks.

Authors:  Samuel H Kimball; P Ewen King-Smith; Jason J Nichols
Journal:  Invest Ophthalmol Vis Sci       Date:  2010-08-04       Impact factor: 4.799

2.  Retrobulbar hemodynamics and corneal surface temperature in glaucoma surgery.

Authors:  Fernando Galassi; Barbara Giambene; Andrea Corvi; Giacomo Falaschi; Ugo Menchini
Journal:  Int Ophthalmol       Date:  2007-10-19       Impact factor: 2.031

3.  The effect of temperature on gene silencing by siRNAs: implications for silencing in the anterior chamber of the eye.

Authors:  Paul Russell; Erin Walsh; WeiPing Chen; Andreas Goldwich; Ernst R Tamm
Journal:  Exp Eye Res       Date:  2006-02-07       Impact factor: 3.467

4.  Analysis of normal human eye with different age groups using infrared images.

Authors:  U Rajendra Acharya; E Y K Ng; Gerk Chang Yee; Tan Jian Hua; Manjunath Kagathi
Journal:  J Med Syst       Date:  2009-06       Impact factor: 4.460

Review 5.  Four characteristics and a model of an effective tear film lipid layer (TFLL).

Authors:  P Ewen King-Smith; Melissa D Bailey; Richard J Braun
Journal:  Ocul Surf       Date:  2013-07-12       Impact factor: 5.033

Review 6.  [Meibomian glands. Part II: physiology, characteristics, distribution and function of meibomian oil].

Authors:  E Knop; N Knop; F Schirra
Journal:  Ophthalmologe       Date:  2009-10       Impact factor: 1.059

7.  Biodegradable Thermosensitive PLGA-PEG-PLGA Polymer for Non-irritating and Sustained Ophthalmic Drug Delivery.

Authors:  Pui Shan Chan; Jia Wen Xian; Qingqing Li; Chun Wai Chan; Sharon S Y Leung; Kenneth K W To
Journal:  AAPS J       Date:  2019-04-24       Impact factor: 4.009

Review 8.  Impact of Ocular Surface Temperature on Tear Characteristics: Current Insights.

Authors:  Ankit M Shah; Anat Galor
Journal:  Clin Optom (Auckl)       Date:  2021-02-15

9.  The effect of pH, dilution, and temperature on the viscosity of ocular lubricants--shift in rheological parameters and potential clinical significance.

Authors:  M Q Rahman; K-S Chuah; E C A Macdonald; J P M Trusler; K Ramaesh
Journal:  Eye (Lond)       Date:  2012-10-19       Impact factor: 3.775

10.  Effects of motion and b-value on apparent temperature measurement by diffusion-based thermometry MRI: eye vitreous study.

Authors:  Jamal J Derakhshan; Neda Parvin; Laurie A Loevner; Felix W Wehrli; Robert C McKinstry
Journal:  Med Phys       Date:  2020-09-02       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.