Literature DB >> 15893898

The value of contrast and subtraction arthrography in the assessment of aseptic loosening of total hip prostheses: a meta-analysis.

Olivier P P Temmerman1, Ide C Heyligers, Gerrit J J Teule, Otto S Hoekstra, Pieter G H M Raijmakers.   

Abstract

OBJECTIVE: To summarize and compare the diagnostic accuracy of contrast and subtraction arthrography in the assessment of aseptic loosening of total hip arthroplasties.
DESIGN: This meta-analysis was performed using methods described by the Cochrane Methods Group on Systematic Reviews of Screening and Diagnostic Tests. We included original, English-language papers published between January 1975 to October 2004 that examined contrast-enhanced arthrography with or without subtraction for diagnosis of loosening of total hip prostheses. A qualitative and quantitative analysis was performed by two investigators.
RESULTS: With regard to the acetabular component, pooled sensitivity and specificity for contrast arthrography was 70% (95% confidence interval, 52-84) and 74% (95% CI, 53-87), respectively. Subtraction arthrography had a significantly higher sensitivity of 89% (95% CI, 84-93) (p=0.01), with a similar specificity of 76% (95% CI, 68-82). For the femoral component, pooled sensitivity and specificity for contrast arthrography were 63% (95% CI, 53-72) and 78% (95% CI, 68-86). Pooled estimates for subtraction arthrography revealed a significantly higher sensitivity of 86% (95% CI, 74-93) (p=0.003). Specificity was 85% (95% CI, 77-91) and was similar to the data of contrast arthrography (p=0.23).
CONCLUSION: Using the present data we found that the subtraction arthrography is a sensitive technique for detection of loosening of total hip prostheses, offering added value over contrast arthrography, especially for evaluation of the femoral component.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15893898     DOI: 10.1016/j.ejrad.2005.02.008

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  2 in total

1.  Acoustic monitoring (RFM) of total hip arthroplasty - Results of a cadaver study.

Authors:  A C Unger; H Cabrera-Palacios; A P Schulz; Ch Jürgens; Andreas Paech
Journal:  Eur J Med Res       Date:  2009-06-18       Impact factor: 2.175

2.  Sentinel node detection in patients with thyroid carcinoma: a meta-analysis.

Authors:  P G H M Raijmakers; M A Paul; P Lips
Journal:  World J Surg       Date:  2008-09       Impact factor: 3.352

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.