Literature DB >> 15891715

Tissue-engineered collagen meniscus implants: 5- to 6-year feasibility study results.

J Richard Steadman1, William G Rodkey.   

Abstract

PURPOSE: In this feasibility study, a 5- to 6-year clinical follow-up evaluation was conducted on 8 patients who had undergone reconstruction of 1 injured medial meniscus with a tissue-engineered collagen meniscus implant. The hypothesis was that these patients would show significant clinical improvement over their preoperative status and would have maintained their status determined at the 2-year follow-up evaluation. TYPE OF STUDY: Prospective longitudinal feasibility study follow-up evaluation.
METHODS: Eight patients underwent arthroscopic placement of a collagen meniscus implant by a single surgeon to reconstruct and restore the irreparably damaged medial meniscus of 1 knee. All patients returned for clinical, radiographic, magnetic resonance imaging, and arthroscopic examinations an average of 5.8 years (range, 5.5-6.3 y) after collagen meniscus implant placement.
RESULTS: Lysholm scores improved significantly (P = .045) from 75 preoperatively to 88 at most recent follow-up evaluation. Average Tegner activity scores improved significantly (P = .001) from 3 to 6. Patient self-assessment improved significantly (P = .046) from 2.4 to 1.9 (1 = normal, 4 = severely abnormal). Pain scores improved from 23 to 11 (0 = no pain, 100 = worst pain). Imaging studies confirmed that the chondral surfaces of the medial compartment had not degenerated further since the placement of the implant 5.8 years earlier. Relook arthroscopy with direct measurement of the newly generated tissue revealed 69% defect filling. Histologic assessment of tissue biopsy specimens from 3 patients showed the presence of fibrocartilage with a uniform extracellular matrix.
CONCLUSIONS: The meniscus-like tissue that developed after collagen meniscus implant placement has maintained its structure and functioned without negative effects for more than 5 years. The hypothesis was affirmed that these patients were improved significantly compared with their preoperative status and unchanged compared with 2-year evaluations. LEVEL OF EVIDENCE: Level IV.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15891715     DOI: 10.1016/j.arthro.2005.01.006

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  35 in total

1.  Meniscus Repair and Regeneration: A Systematic Review from a Basic and Translational Science Perspective.

Authors:  John Twomey-Kozak; Chathuraka T Jayasuriya
Journal:  Clin Sports Med       Date:  2020-01       Impact factor: 2.182

Review 2.  Meniscus allograft transplantation: a current concepts review.

Authors:  James H Lubowitz; Peter C M Verdonk; John B Reid; René Verdonk
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-02-28       Impact factor: 4.342

Review 3.  Engineering orthopedic tissue interfaces.

Authors:  Peter J Yang; Johnna S Temenoff
Journal:  Tissue Eng Part B Rev       Date:  2009-06       Impact factor: 6.389

4.  Arthroscopic lateral collagen meniscus implant in a professional soccer player.

Authors:  Stefano Zaffagnini; Giulio Maria Marcheggiani Muccioli; Alberto Grassi; Tommaso Bonanzinga; Giuseppe Filardo; Angello Canales Passalacqua; Maurilio Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-05-10       Impact factor: 4.342

5.  "Changes in articular cartilage after meniscectomy and meniscus replacement using a biodegradable porous polymer implant" by Hannink et al.

Authors:  Philippe Beaufils
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-09-10       Impact factor: 4.342

Review 6.  The current state of scaffolds for musculoskeletal regenerative applications.

Authors:  Benjamin D Smith; Daniel A Grande
Journal:  Nat Rev Rheumatol       Date:  2015-03-17       Impact factor: 20.543

7.  What is the best way to fix a polyurethane meniscal scaffold? A biomechanical evaluation of different fixation modes.

Authors:  Francois Hardeman; Kristoff Corten; Michiel Mylle; Bert Van Herck; René Verdonk; Peter Verdonk; Johan Bellemans
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-12       Impact factor: 4.342

8.  Midterm follow-up after implantation of a polyurethane meniscal scaffold for segmental medial meniscus loss: maintenance of good clinical and MRI outcome.

Authors:  Karl F Schüttler; Felix Haberhauer; Markus Gesslein; Thomas J Heyse; Jens Figiel; Olaf Lorbach; Turgay Efe; Philip P Roessler
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-08-23       Impact factor: 4.342

9.  Biodegradable polyurethane meniscal scaffold for isolated partial lesions or as combined procedure for knees with multiple comorbidities: clinical results at 2 years.

Authors:  Elizaveta Kon; Giuseppe Filardo; Stefano Zaffagnini; Alessandro Di Martino; Berardo Di Matteo; Giulio Maria Marcheggiani Muccioli; Maurizio Busacca; Maurilio Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-12-06       Impact factor: 4.342

10.  Follow-up of collagen meniscus implants by MRI.

Authors:  E Genovese; M G Angeretti; M Ronga; A Leonardi; R Novario; L Callegari; C Fugazzola
Journal:  Radiol Med       Date:  2007-10-21       Impact factor: 3.469

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.