Literature DB >> 15890451

Effects of a time-varying strong magnetic field on transient increase in Ca2+ release induced by cytosolic Ca2+ in cultured pheochromocytoma cells.

Toshitaka Ikehara1, Hisao Yamaguchi, Keiko Hosokawa, Hitoshi Houchi, Ki Ho Park, Kazuo Minakuchi, Hideki Kashimoto, Mitsuo Kitamura, Yohsuke Kinouchi, Kazuo Yoshizaki, Hiroshi Miyamoto.   

Abstract

Exposure of pheochromocytoma (PC 12) cells to a time-varying 1.51 T magnetic field inhibited an increase in the intracellular Ca2+ concentration ([Ca2+]i) induced by addition of caffeine to Ca(2+)-free medium. This inhibition occurred after a 15-min exposure and was maintained for at least 2 h. [Ca2+]i sharply increased in cells loaded with cyclic ADP-ribose, and 2-h exposure significantly suppressed the increase. Addition of ATP induced a transient increase in intracellular Ca2+ release mediated by IP3 receptor, and this increase was strongly inhibited by the exposure. Results indicated that the magnetic field exposure strongly inhibited Ca2+ release mediated by both IP3 and ryanodine receptors in PC 12 cells. However, thapsigargin-induced Ca2+ influx (capacitative Ca2+ entry) across the cell membrane was unaffected. The ATP content was maintained at the normal level during the 2-h exposure, suggesting that ATP hydrolysis was unchanged. Therefore, Mg2+ which is known to be released by ATP hydrolysis and inhibit intracellular Ca2+ release may not relate the exposure-caused inhibition. Eddy currents induced in culture medium appear to change cell membrane properties and indirectly inhibit Ca2+ release from endoplasmic reticulum and other Ca2+ stores in PC 12 cells.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15890451     DOI: 10.1016/j.bbagen.2005.03.008

Source DB:  PubMed          Journal:  Biochim Biophys Acta        ISSN: 0006-3002


  2 in total

1.  Optimization of electric pulse amplitude and frequency in vitro for low voltage and high frequency electrochemotherapy.

Authors:  Zeinab Shankayi; S M P Firoozabadi; Zohair Saraf Hassan
Journal:  J Membr Biol       Date:  2013-11-23       Impact factor: 1.843

2.  Magnetoreception system in honeybees (Apis mellifera).

Authors:  Chin-Yuan Hsu; Fu-Yao Ko; Chia-Wei Li; Kuni Fann; Juh-Tzeng Lue
Journal:  PLoS One       Date:  2007-04-25       Impact factor: 3.240