Prospective evaluation of nocturnal oximetry for detection of sleep-related breathing disturbances in patients with chronic heart failure.

Frédéric Sériès1, R John Kimoff, Debra Morrison, Marie Helene Leblanc, Mark Smilovitch, Jonathan Howlett, Alexander G Logan, John S Floras, T Douglas Bradley.   

Abstract

BACKGROUND: Because patients with chronic heart failure (CHF) can benefit from specific treatment for coexisting obstructive and central sleep apnea (CSA), there is a need to develop accurate screening tools to identify or exclude these sleep-related breathing disturbances (SRBDs) in patients with CHF.
OBJECTIVES: To evaluate, prospectively, the diagnostic value of nocturnal home oximetry in identifying SRBD in CHF patients and in distinguishing central events from obstructive events.
DESIGN: Blinded comparison of hospital and home oximetry, and polysomnographic nocturnal recordings
SETTING: Cardiac heart failure and sleep clinics in three tertiary referral centers. PATIENTS: Fifty consecutive patients who were investigated for participation in the Canadian Continuous Positive Airway Pressure Trial for Congestive Heart Failure with Central Sleep Apnea and were recruited from three different centers. MEASUREMENTS AND
RESULTS: Patients underwent two oximetry recordings, one at home and one during a polysomnographic study. The criterion for an SRBD was the presence of > 15 apneas and hypopneas per hour of sleep during polysomnography or an oxygen desaturation index of > 10 events per hour during oximetry. The pattern of desaturation/resaturation during oximetry was also examined to distinguish obstructive events from central events. Using a 2% fall in pulse oximetric saturation as the criterion for oxygen desaturation, home oximetry had a 85% sensitivity and a 93% specificity (p < 0.001) for detecting an SRBD. However, the desaturation/resaturation pattern did not accurately distinguish between obstructive events and central events (eg, 100% sensitivity, 17% specificity for identifying CSA). The interpretation of the oximetry recording was highly consistent between scorers (p < 0.001).
CONCLUSIONS: Overnight home oximetry is a sensitive and specific tool for identifying SRBDs in patients with CHF, but not for distinguishing between obstructive and central events in such patients.

Entities:  

Mesh:

Year:  2005        PMID: 15888821     DOI: 10.1378/chest.127.5.1507

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  21 in total

Review 1.  Sleep in congestive heart failure.

Authors:  Bhavneesh Sharma; Robert Owens; Atul Malhotra
Journal:  Med Clin North Am       Date:  2010-05       Impact factor: 5.456

2.  Polysomnography underestimates altered cardiac autonomic control in patients with obstructive sleep apnea.

Authors:  C Jilek; J Gebauer; F Muders; M Arzt; G Riegger; M Pfeifer; R Wensel
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2012-03

Review 3.  [Perioperative management of patients with obstructive sleep apnoea].

Authors:  J Schnoor; J Ilgner; M Hein; M Westhofen; R Rossaint
Journal:  Anaesthesist       Date:  2009-02       Impact factor: 1.041

4.  Obstructive sleep apnea and heart failure.

Authors:  Andrew D Calvin; Felipe N Albuquerque; Taro Adachi; Virend K Somers
Journal:  Curr Treat Options Cardiovasc Med       Date:  2009-12

5.  Aortic dissection is associated with intermittent hypoxia and re-oxygenation.

Authors:  Ryo Naito; Kenichi Sakakura; Takatoshi Kasai; Tomotaka Dohi; Hiroshi Wada; Yoshitaka Sugawara; Norifumi Kubo; Suguru Yamashita; Koji Narui; Sugao Ishiwata; Minoru Ohno; Junya Ako; Shin-ichi Momomura
Journal:  Heart Vessels       Date:  2011-05-15       Impact factor: 2.037

6.  [Screening for sleep apnea in cardiovascular patients in clinical routine].

Authors:  W S Mäuser; S Sandrock; L Kotzott; H Bonnemeier
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2012-03

7.  Management plan to reduce risks in perioperative care of patients with presumed obstructive sleep apnea syndrome.

Authors:  Bhargavi Gali; Francis X Whalen; Peter C Gay; Eric J Olson; Darrell R Schroeder; David J Plevak; Timothy I Morgenthaler
Journal:  J Clin Sleep Med       Date:  2007-10-15       Impact factor: 4.062

8.  Examination of pulse oximetry tracings to detect obstructive sleep apnea in patients with advanced chronic obstructive pulmonary disease.

Authors:  Adrienne S Scott; Marc A Baltzan; Norman Wolkove
Journal:  Can Respir J       Date:  2014-02-12       Impact factor: 2.409

Review 9.  Cheyne-stokes respiration in patients with heart failure.

Authors:  Laila AlDabal; Ahmed S BaHammam
Journal:  Lung       Date:  2009-12-03       Impact factor: 2.584

10.  Detection of sleep disordered breathing and its central/obstructive character using nasal cannula and finger pulse oximeter.

Authors:  Dirk Sommermeyer; Ding Zou; Ludger Grote; Jan Hedner
Journal:  J Clin Sleep Med       Date:  2012-10-15       Impact factor: 4.062

View more